Temperature Forcing System/ Thermal Stream Head
AES -115℃~225℃- Time switching10s~20s
- KältemittelR404A/R23/R14/R508B
- Kühlwasser0.6m³/h~3m³/h
- Leistungsbereich3.7kW~7.5kW
Produktdaten herunterladen
![](https://www.lneya.com/wp-content/uploads/2024/05/banner2-1024x288.jpg)
TEMP SHOCK TEST AIRFLOW HOOD
1/CHARACTERISTIC ANALYSIS
2/LOOP TEST
3/IMPACT TEST
4/FAILURE ANALYSIS
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
Detaillierte Parameter
Modell | AES-4535 | AES-6035 | AES-8035 | AES-A1035W | AES-A1235W | |
AES-4535W | AES-6035W | AES-8035W | ||||
Temp. Bereich | -45℃~225℃ | -60℃~225℃ | -80℃~225℃ | -100℃~225℃ | -120℃~225℃ | |
Heizleistung | 3,5 kW | 3,5 kW | 3,5 kW | 4,5 kW | 4,5 kW | |
Temp. Control Accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. Conversion Time | -25℃ to 150℃ Approximately 10S 150℃ to -25℃ Approximately 20s |
-45℃ to 150℃ Approximately 10S 150℃to -45℃ Approximately 20s |
-55℃ to 150℃ Approximately 10S 150℃to -55℃ Approximately 15s |
-70℃ to 150℃ Approximately 10S 150 ℃to -70℃ Approximately 20s |
-80℃ to 150℃ Approximately 11S 150℃to -80℃ Approximately 20s |
|
Air Requirement | Air Cleaner<5um | |||||
Air Oil Content:<0.1ppm | ||||||
Air Temp&Humidity:5℃~32℃ 0~50%RH | ||||||
Air Handing Capacity | 7m3/h ~ 25m3/h Pressure 5bar~7.6bar | |||||
System Pressure Dispiay | Der Druck des Kältesystems wird durch ein Manometer (Hochdruck, Niederdruck) ermittelt; | |||||
Der Druck im Kreislaufsystem wird von einem Drucksensor erfasst und auf dem Touchscreen angezeigt. | ||||||
Controller | Siemens PLC, Fuzzy PID Control algorithm. | |||||
Temp. Steuerung | Control of outlet temperature | |||||
Programmierbar | 5 Verfahren können entwickelt werden, und jedes Programm kann aus 40 Schritten bestehen | |||||
Kommunikationsprotokoll | Ethernet Interface TCP/IP Protocol. | |||||
Internal Temp. Feedback | Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) . | |||||
Temp. Feedback | T Temperature Sensor | |||||
Kompressionsmotor | Taikang,France | Taikang,France | Taikang,France | Italy Duling | Italy Duling | |
Verdunstungsmesser | Double-pipe (heat) Exchanger | |||||
Calorifier | Flanged Barrel Heater | |||||
Kältetechnik-Zubehör | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves). | |||||
Bedienfeld | LNEYA kundenspezifischer 7-Zoll-Farb-Touchscreen, Temperaturkurvenanzeige\ EXCEL-Datenexport | |||||
Sichere Bewachung | Mit Selbstdiagnosefunktion; Phasenfolge-Phasenunterbrecher, Gefrierschrank-Überlastschutz; Hochspannungsdruckschalter, Überlastrelais, thermische Schutzeinrichtung und andere Sicherheitsschutzfunktionen. | |||||
Kryogen | Topsubmixed Refrigerant | |||||
External Insulation Hose | 8m DN32 fast coupling clamp for easy outgoing insulation hose | |||||
Kältemittel | R404A | R404A/R23 | R404A/R508B | R404A/R23/R14 | R404A/R23/R14 | |
Shape Dimension (Wind)cm | 54*69*132 | 54*69*132 | 75*73*133 | 80*120*185 | 100*150*185 | |
Shape Size (Water)cm | 54*69*132 | 54*69*132 | 75*73*133 | 70*100*175 | 80*120*185 | |
Air-Cooled Type | Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan. | |||||
Water-Cooled Type W | Typ W ist wassergekühlt | |||||
Water-Cooled Condenser | Sleeve type heat exchanger (Paris/ Shen’s) | |||||
Cooling Water Quantity At 25℃ | 0.6m3/h | 1.2m3/h | 1.6m3/h | 2,6m3/h | 3m3/h | |
Quelle 380V 50HZ | 3.7kW max | 5kW max. | 5kW max. | 6.8kW max | 7,5 kW max. | |
Quelle | Anpassbar 460V 60HZN 220V 60HZ dreiphasig | |||||
Material der Schale | Cold rolled sheet spray (Standard Colour 7035). | |||||
Temp. Spread | High Temperature To +300℃ |
Beschreibung des Produkts
The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test.
It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster.
Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.
Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.
Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.
PRODUCT ADVANTAGES
![](https://www.lneya.com/wp-content/uploads/2024/04/03-8.jpg)
1/LCD 2/insulation hose 3/Mechanical arm 4/Heating head 5/Heat hood
![](https://www.lneya.com/wp-content/uploads/2024/04/04-5.jpg)
1/Oil mist separator 2/Micro mist separator 3/Air dryer 4/Pressure reducing valve
![](https://www.lneya.com/wp-content/uploads/2023/05/aes_09.gif)
REQUEST A QUOTE
Vielleicht interessieren Sie sich auch für diese Produkte
FLT-100℃~80℃ Niedertemperatur-Kaskade
Genauigkeit der Temperatur ±0.1℃ Durchflusskontrolle 12~45/min
FLTZ -30℃~40℃ Doppelte Frequenzumwandlung Serie
Genauigkeit der Temperatur ±0.1℃ Durchflusskontrolle 15~45/min 6bar max Leistungsbereich 380V 3,5kW
Wärmeaustauschkühler ETCU
Genauigkeit der Temperatur ±0.3℃ Leistungsbereich 380V 0,6kW~1,6kW
Conventional Type FLT -45℃~80℃
Genauigkeit der Temperatur ±0.1℃ Durchflusskontrolle 25~75/min 6bar max Kältemittel R404A Leistungsbereich 380V 3,5kW~16kW
Laden...
已经是到最后一篇内容了!