Maintenance and maintenance of battery pack test temperature simulation chiller
The battery pack test temperature simulation chiller is more and more widely used in enterprises, but the subsequent maintenance and maintenance are also more important. Here is a brief introduction to some maintenance and maintenance methods.
1. The temperature of the battery pack that does not need to be opened is not closed before the start-up to simulate the water inlet valve of the condenser on the chiller, resulting in water leakage. Part of the cooling return water flows away from the condenser of the non-starting unit, reducing the cooling water flow in the condenser of the operating unit, causing the condensation pressure to rise, the operating current of the main engine to increase, and the cooling capacity of the unit to decrease. Stopping the operation not only wastes electricity, but also reduces the cooling effect, and is easy to damage the equipment.
2. Before starting up, close the water inlet valve of the condenser of the unit that does not need to be operated to prevent water leakage. Open the water inlet and outlet valves on the condenser of the unit to be operated (generally the outlet valve is normally open, the water inlet valve is opened and closed according to needs. The condenser and the evaporator are the same) and turn on the corresponding cooling water pump to adjust the water inlet and outlet pressure of the condenser.
3. If the pointer of the pressure gauge of the water inlet and outlet of the condenser swings too much, it means that there is air in the equipment system, and the air needs to be exhausted to continue to the next step after the pressure gauge indicates normal.
4. It adopts an intelligent main control board, and the LED display is stable and durable, with multiple settings and fault display functions; it is equipped with a water outlet pressure gauge, which is convenient for observing pressure and flow.
Verwandte Empfehlungen
-
Matters Needing Attention in Maintenance of Low Temperature Chamber
14392.The temperature and humidity of the low temperature chamber are the important factors affecting the performance of the instrument. It can cause the corrosion of mechanical parts, reduce the smoothness of metal mirror, and cause the error or perf...
Details anzeigen -
Wie kann man den Verflüssigungsdruck der Heizungsumwälzanlage reduzieren?
1851Während des Betriebs der Heizungsumwälzanlage führt die Temperaturänderung im Gerät zu einer Änderung des Verflüssigungsdrucks. Besonders im Sommer, wenn der Verflüssigungsdruck zu hoch ist, wird die Leistungsaufnahme des Kompressors...
Details anzeigen -
Electric Vehicle Motor Test Cooling System Chiller Instructions
2048With the continuous development of new energy vehicles, Chiller, the electric motor motor test cooling system, is also developing. The new chiller for motor testing of new energy vehicles can adaptively adjust the chiller according to the dynamic ...
Details anzeigen -
Warum braucht der Glasreaktor im Betrieb einen Heizungs-Kühlungsumlauf?
1435The glass vacuum reactor is of double-layer glass design. The inner layer is filled with reaction solvent for stirring reaction, and the interlayer can be connected with different cold and heat sources (freezing liquid, hot water or hot oil) for c...
Details anzeigen