Cold and hot shock constant temperature and humidity test chamber operation steps
When selecting the appropriate model of the LNEYA hot and cold shock constant temperature and humidity test chamber, you need to pay attention to the operation and installation steps. The user needs to be well prepared for the installation work.
The hot and cold shock constant temperature and humidity test chamber should be noted before use. The power supply voltage should be turned on. After the fan is started, open the door and select the required impact height. Then close the door and press the up and down position. Then stop rising.
Then, open the door and insert the safety pin to protect it in the future operation. Place the tested object in the center of the thermal shock constant temperature and humidity test chamber, and then place the crossbar on the sample. Hold the battery at the center, dial the safety latch, and close the door. Press the impact button and the falling ball weight is free to drop and complete a test.
The hot and cold shock constant temperature and humidity test chamber should be noted in use. The test sample should be a non-deformed sample or a well-packaged sample to avoid affecting the test conclusion. Before placing the sample for each operation, be sure to insert the full plug. Well, it is strictly forbidden to operate without a safety plug to avoid unnecessary safety accidents.
The installation proposal of the thermal shock constant temperature and humidity test chamber shall be installed by a special operator, and the installation of the external operator shall be avoided as much as possible to avoid damage to the equipment.
Verwandte Empfehlungen
-
The maintenance and maintenance of an ultra-low temperature refrigerator
1914The maintenance and maintenance of an ultra-low temperature refrigerator are very important for normal usage and prolonging its life. If the inaccurate temperature control often results in the damage of the protected objects, which will greatly af...
Details anzeigen -
Beschreibung der Eigenschaften von Kühlkörpern bei der Chip-Temperaturkontrolle
1971Mit der kontinuierlichen Entwicklung elektronischer Chips schreitet auch deren Wärmeableitungstechnologie voran. Die LNEYA Chip-Temperaturkontrolltechnologie wird zusammen mit den Chip-Testgeräten kontinuierlich gefördert. Der Entwicklungstrend der modernen Computerchips...
Details anzeigen -
Temperaturkontrolleinheit für die Extraktion von chemischen Rohstoffen der chinesischen Medizin - TCU
1846Der Herstellungsprozess von Rohstoffen für die traditionelle chinesische Medizin ist relativ kompliziert: langer Prozess, viele Rohrleitungen und komplizierte Vorgänge; und die meisten Rohstoffe für die Zubereitung sind instabil, z.B. durch hohe Umweltparameter...
Details anzeigen -
Basic maintenance of high and low temperature refrigeration circulating pumps
2112Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protect...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant










