Basic maintenance of high and low temperature refrigeration circulating pumps
Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protection device of the high and low temperature refrigeration cycle pump group will stop and even cause malfunction due to the condensing temperature and the corresponding condensing pressure being too high. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, the cold water temperature protection device will stop, or the low temperature protection device will stop due to the evaporation temperature and the corresponding evaporation pressure being too low, even leading to the evaporator. Cold water freezes and damages equipment.
Therefore, the boot sequence is: (must be strictly observed) Cooling tower fan on → cooling water pump on → cold water pump on → high and low temperature refrigeration cycle pump group. The shutdown sequence of the high and low temperature refrigeration circulating pump set is: (must be strictly observed) The equipment group stops → the cooling tower fan stops → the cooling water pump stops → the cold water pump stops. When the machine is shut down, the equipment group should be shut down half an hour before leaving work. The cold water pump is shut down after work, which is conducive to saving energy, avoiding downtime and protecting the unit. Before running the high and low temperature refrigeration cycle pump refrigeration cycle, make sure that the heating cycle pipe valves are all closed.
Maintenance of high and low temperature refrigeration circulating pumps is indispensable. At the same time, the operator needs to have certain operational knowledge of the equipment and will not find operational faults.
Verwandte Empfehlungen
-
Design und Testtechnologie von Hochtemperatur-Umweltkammern Vertrieb
20811. Temperaturauswahl (1) Die Klimazonen der Region; ob das Produkt in der Nähe des Heizgeräts der Sonneneinstrahlung ausgesetzt ist; Umgebungsluft, Sonneneinstrahlung und Wege der Wärmeübertragung von Heizgeräten auf Produkte;...
Details anzeigen -
LNEYA Flüssigkühllösung für Rechenzentren Flüssigkeitsgekühlte CDU-Verteilereinheit
1938LNEYA Flüssigkühler für Rechenzentren CDU
Details anzeigen -
Disadvantages and advantages of general heat transfer oil heating circulation system
1621The heat conduction oil heating circulation system adopts a fully closed loop structure to directly act on the heat energy to the heated medium. Its advantages are: (1) Due to the continuous renewal of the heat transfer surface, the heat loss is s...
Details anzeigen -
Instructions for the use of temperature control equipment for isolation reactors
1335The reaction kettle is a commonly used reactor in pharmaceutical and chemical production. The temperature control equipment of the isolated reaction kettle is realized by controlling two doors, namely the heating water valve and the cooling water ...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant