What should I pay attention to when placing high and low temperature closed loop circulators?
There are certain differences in the size and performance of high and low temperature fully enclosed circulators from different manufacturers. Users need to pay attention to the placement position when placing them after purchase. If the placement position is not good, it is not conducive to the operation of high and low temperature fully enclosed circulators.
In the installation of high and low temperature fully enclosed circulators, the heat dissipation efficiency of the high and low temperature closed loop circulators should be considered and the maintenance should be easy. The floor of the equipment must be flat and have sufficient strength (3.4 N/m2 or higher). Select a dust. And locations where vibration effects are small.
High and low temperature fully enclosed circulators are to be installed in a dry room with a high and low temperature fully enclosed circulator, and where there is a power supply and sewer nearby, the equipment should be installed in a place with little dust. The wind condition causes no oxygen deficiency to occur even if the refrigerant (fluorohydrocarbon) leaks from the equipment.
Good ventilation should be maintained around the installation of high and low temperature fully enclosed circulators. During operation, the device will radiate heat. If it is air-cooled, it will directly discharge heat through the condensed air. In the case of small room and poor ventilation, the indoor temperature will rise rapidly, causing the machine to stop running and alarm. . Installation of high and low temperature fully enclosed circulators should be kept away from flammable or explosive materials or other substances that may generate high heat.

When placing it, be careful not to let the sun directly project onto the device. When the device is used beyond this range, the safety device will start or the device will stop running. In order to achieve stable performance of the high and low temperature closed loop circulator, the installation room of the high and low temperature closed loop circulator should be air-conditioned to maintain the indoor temperature between 10 ° C and 30 ° C.
The atmospheric environment of the high and low temperature fully enclosed circulator installation site is consistent with the general indoor air-conditioned atmospheric environment. If organic solvents, plasticizers, acids, alkalis or other chemicals are present in the air, the parts or coatings of the equipment may be corroded and destroyed.
The precautions for placing the high and low temperature fully enclosed circulators should be taken seriously by our operators. Read the instruction manual in detail.
Verwandte Empfehlungen
-
Häufige Fehler von Salzsprüh-Umweltkammern
1031Die Anwender in den Unternehmen sind oft ratlos, wenn es um häufige Fehler in der Salzsprühnebel-Umgebungskammer geht. Aus diesem Grund hat Wuxi LNEYA, ein Hersteller von Salzsprühnebel-Umgebungskammern, speziell die damit verbundenen häufigen Fehler...
Details anzeigen -
Theorie des Eisflusses, Eiswasserqualität, Durchfluss und Druck der Eiswassermaschine
844Die Enthärtung des Wassers ist ebenfalls ein wichtiges Problem bei der Verwendung von Kältemaschinen, und auch der pH-Wert des Wassers muss ständig überwacht werden. Der optimale pH-Wert sollte bei 7 liegen. Ein pH-Wert von mehr als 7 führt zu starker Korrosion...
Details anzeigen -
Heat transfer oil of explosion-proof cooling and heating circulator
941Explosion proof cooling and heating circulator is a commonly used temperature control equipment in laboratories. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc. ...
Details anzeigen -
Wie geht man mit Chipausfällen bei der Prüfung integrierter Schaltkreise um?
1172The integrated circuit chip test is used in various chips, semiconductors, and component tests. Once the chip fails, the test work will stop. Therefore, the ineffective user of the integrated circuit chip test needs to know clearly. The purpose of...
Details anzeigen