Selection of ultra-low temperature chiller supporting the glass reactor
In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen is low, and this refrigeration method is welcomed by some users, both in experiments and in production. However, due to the low boiling point of liquid nitrogen (minus 195.8°C), the latent heat is small and it is easy to evaporate. There are also big problems with using liquid nitrogen refrigerators safely.
In the storage, transportation and application of liquid nitrogen, it is necessary to have storage and application equipment with good thermal insulation performance. Most of the liquid nitrogen related equipment and pipeline fittings on the market adopt double-walled vacuum container structure. The key factor affecting the performance of this vacuum container and accessories is the vacuum degree of the interlayer. Moreover, the use of liquid nitrogen puts forward higher requirements on the reactor temperature control method, heat preservation measures, material properties, equipment sealing and pressure control, and environmental safety measures. Glass reactors cooled with liquid nitrogen must still retain the advantage of being transparent and visible during the reaction. Moreover, liquid nitrogen is a health hazard: skin contact with liquid nitrogen can cause frostbite. If the nitrogen produced by vaporization under normal pressure is excessive, the partial pressure of oxygen in the air will drop, causing hypoxia and suffocation. Guanya Refrigeration’s ultra-low temperature freezer adopts the single-machine cascade refrigeration process, and the low temperature can reach minus 150 degrees; it adopts the secondary supercooling technology, and the refrigeration is rapid.
Verwandte Empfehlungen
-
Hot and cold dynamic constant temperature control equipment cryopump installation points
1155The performance of each component in the cold and heat source dynamic constant temperature control equipment is different. We must make full use of each accessory to make the equipment run better. The cryopump is one of the main accessories, and i...
Details anzeigen -
What should I do if the heat transfer oil heater is not enough?
1064The heat transfer oil electric heating device is also called high and low temperature integrated machine, refrigeration and heating integrated machine, refrigeration heating dynamic temperature control system, and replaces the traditional electric...
Details anzeigen -
Wie kann man das Expansionsventil eines Tiefkühlgeräts reparieren?
1084Der effektive Betrieb eines Tiefkühlgeräts hängt von der erforderlichen Kühlwirkung ab. Es ist wichtig, das Expansionsventil zu korrigieren, wenn eine bessere Kühlwirkung gewünscht wird. Wie kann man also das Expansionsventil eines Tiefkühlgeräts reparieren?Während ...
Details anzeigen -
Beschreibung der Funktionsweise der Hoch- und Tieftemperatur-Schlagprüfkammer
1046Spot hohe und niedrige Temperatur Auswirkungen Prüfkammer, auch bekannt als Drei-Box hohe und niedrige Temperatur Auswirkungen Prüfkammer, hohe und niedrige Temperatur Auswirkungen Prüfkammer ist vor allem der niedrigen Temperatur Speicherkammer, hohe Temperatur Speicherkammer...
Details anzeigen