General high and low temperature integrated machine valve repair detailed description
The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the packing gland can be tightened. If the leak cannot be eliminated, the packing should be replaced. When replacing, the valve stem must be screwed out to the end. Use the filler needle to pull out the old packing, then screw the prepared new packing in turn, and then tighten the gland.
In conventional high and low temperature integrated machine engineering, the valve core of a large diameter valve is sealed by a layer of babbitt or fluoroplastic. The back of the spool also has a layer of babbitt so that when the stem is rotated out of position, the working fluid can be sealed without leaking outward along the stem. After the valve is disassembled, first straighten the stem to deburr, then replace the valve’s babbitt alloy. At the same time, the valve seat should also be ground to make the valve core and the valve seat tight. For small cast steel or brass valve spools, the seal of this valve is obtained by a line of metal contact, hence the line seal. Because it is a wire seal, the valve seat and the valve core should be carefully ground to obtain a satisfactory sealing effect. After the valve is overhauled, the air tightness test shall be carried out in accordance with the relevant requirements.
The repair of the safety valve in the explosion-proof high-temperature integrated machine refrigeration system is also roughly the same as above, but since the babbitt alloy is soft, it is often difficult to return to the original position after the safety valve is operated once due to overpressure, so when the pressure is reduced to the closing pressure At the time, it is still not tight. In order to overcome this drawback, some products have changed the Babbitt alloy to a nickel-chromium-titanium (harder) alloy, or replaced with polytetrafluoroethylene.
The timely maintenance of conventional high and low temperature integrated machine valves can better help the operation of conventional high and low temperature integrated machines, so it is recommended to solve them in time.
Verwandte Empfehlungen
-
-
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
2016Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...
Details anzeigen -
Was sind die Unterschiede zwischen Tieftemperaturprüfkammer und Kühlung?
1936Die Tieftemperaturprüfkammer, wie der Name schon sagt, dient wahrscheinlich der Durchführung von Tieftemperaturtests. Es ist wichtiger in unserer Kälteanlage. Die kleine Serie von Tieftemperatur-Prüfkammer sagt Ihnen, dass die Kühlung der niedrigen Temperatu...
Details anzeigen -
Wie lässt sich das Problem des Ausfalls der Umwälzpumpe der Kühlanlage lösen?
1679Kühlung Heizgeräte sind in vielen chemischen, pharmazeutischen und Laboranwendungen erforderlich. Dann, wie das Scheitern der Kühlung Heizung Gerät zu lösen ist auch besorgt über, wie es zu lösen? 1. Ausfall der Umwälzpumpe Die Umwälzpumpe...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant