The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


E-Mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Verwandte Empfehlungen
-
Betriebsanleitung für die Kältemaschine, ein Kreislaufsystem für die Temperierung von Laborprozessen
1722Das Wärmeträgermedium des Laborprozess-Temperaturregelkreislaufs verwendet Öl und Wasser. Das Wärmeträgermedium (Wärmeträgeröl oder Wasser), das in den Rohrleitungen zirkulieren muss, wird durch eine elektrische Heizung erwärmt...
Details anzeigen -
LNEYA: Focus on temperature control TCU to build international advanced Chinese instruments
1555Wide temperature range: LNEYA's Chinese and production-grade multi-reactor refrigeration heating temperature control system (temperature control unit TCU) temperature range from -25 ° C to 200 ° C, of course, you can also customize other temperatu...
Details anzeigen -
Es gibt in der Regel drei Möglichkeiten, die Temperatur von Laborreaktoren zu kontrollieren
14661. Manuelle Steuerung: Manuelle Bedienung des Drehknopfes an der Vorderseite des Reaktorsteuergeräts.2. Steuerung über PC: Der PC und der Regler sind über ein Netzwerkkabel verbunden, und die Bedienung erfolgt über den PC.3. Gesteuert durch Thermostat: Silikonöl...
Details anzeigen -
Vorteile von Cold Plate Freezer
1533Die Gefriermethode wird hauptsächlich verwendet, wenn das kapazitive Flüssigkristall-Touchpanel von Smartphones und Tablet-Computern Produktionsfehler aufweist, wie z.B. Blasen, Fremdkörper, schwarze Flecken, weiße Flecken, verrutschte..., und zur Wiederherstellung...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant