Es gibt in der Regel drei Möglichkeiten, die Temperatur von Laborreaktoren zu kontrollieren
1. Manual control: Manually operate the knob on the front of the reactor controller.
2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.
3. Controlled by thermostat: Silicone oil is heated through the thermostat, and the thermostat naturally has a temperature control function. Although the thermostat heating limit (usually 250°C) is not as high as that of electric heating (can be as high as 400-500°C), the thermostat rises and falls smoothly, and the low temperature can reach -60/-80°C.
Our LNEYA laboratory reactor temperature control system belongs to the third category. However, the temperature control range is from -120 degrees to 350 degrees. It adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer oil, improves the heat utilization rate of the system, and realizes rapid temperature rise and fall. Continuous temperature control can be achieved in the temperature range of minus 90 degrees to 195 degrees and minus 70 degrees to 220 degrees without pressure.
Jacketed glass reactors are popular in current chemical experiments. The supporting temperature control equipment has also become a matter of widespread concern in the industry. It is known that the cooling and heating temperature in the reaction process has an absolute influence on the reaction process and results. The analysis of the temperature control equipment’s ability to increase and decrease the temperature of the material has become the basic basis for choosing chiller. Then the cooling and heating capacity is not only estimated by imagination and experience, but requires scientific analysis and calculation methods, and needs to calculate the required heating power and cooling power according to the heating rate and cooling rate.
When our technicians communicate with customers, they will first understand the requirements of engineering parameters, such as high and low temperature, how long is the temperature control time, etc., so as to calculate the cooling power and heating power of the chiller required, and determine the available chiller. model, to give customers the most complete temperature control solution. If you also have this need, you can contact us.
Verwandte Empfehlungen
-
What model of industrial refrigerator is used for freezing workpieces?
1570What is a workpiece freezer-industrial cold-shrink assembly technology-extended life, metal cold treatment is to put a metal or alloy workpiece in a certain medium and heat it to a suitable temperature, and keep it in this temperature for a certai...
Details anzeigen -
Heat sink temperature application note
1696As we all know, the semiconductor industry has certain characteristics, small size, high reliability, wide working range, and has a wide range of applications in the civilian, industrial and other fields of semiconductors, but with the increasing ...
Details anzeigen -
What aspects need to be considered in the external circulation cooling system of the test bench?
1615As we all know, the test room needs to be equipped with a cooling system for vehicle performance and comprehensive transmission, road simulation, electromagnetic compatibility, power battery, vehicle environment and other tests. In the automobile...
Details anzeigen -
How to prevent the freezing pressure of the bearing quick freezing box from being too low?
1803In the refrigeration system of the bearing blast chiller, if the condenser installation is not in the enclosed space, the system's exhaust pressure (condensation pressure) tends to be lower in winter (or low temperature), which is often more commo...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant