Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Verflüssiger: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Verdampfer: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Ethernet-Schnittstelle TCP/IP-Protokoll
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
Die Pumpe mit variabler Frequenz kann den Druck und den Durchfluss des Hydraulikkreislaufs einstellen
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Verwandte Empfehlungen
-
Betriebsanleitung für den Verdampfer eines großen Industriekühlschranks
751Im Betriebsprozess von Wuxi Guanya LNEYA großen industriellen Kühlschrank, aufgrund der großen Anzahl von Teilen und komplex, müssen wir den Betrieb der Komponenten in großen industriellen Kühlschränken zu verstehen. Der Verdampfer ist einer der wichtigsten K...
Details anzeigen -
Precautions for Leakage Inspection of Glycol Chiller
1012The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, ...
Details anzeigen -
-
Inbetriebnahme von Kaltwasserkreislaufanlagen für Chemieunternehmen
604After completing the installation of circulating water chillers in chemical enterprises, certain debugging needs to be carried out for industrial chemical circulating water chillers in the early stage of operation. Only through careful debug...
Details anzeigen