Wie lässt sich das Kühlproblem bei großen Schnellkühlkompressoren lösen?
There are many types of compressors in large-scale quick-freezers, and the brands and models of compressors are different according to different models. Once the compressor temperature is too high, it may cause some failures, so cooling is also an important task.
In the operation of large-scale quick-freezer compressors, cooling is an indispensable part. The compressor should always pay attention to the cooling water. Once the water is cut off, it must be stopped immediately for inspection. Components that require water to be cooled by the compressor include cylinders, intercoolers, compressor aftercoolers, and oil coolers.
For large freezer cylinders and intercoolers, one of the purposes of cooling is to reduce the exhaust temperature so that the exhaust temperature does not exceed the allowable range. It can be seen that after the large-scale quick-freezer compressor is shut off, the cylinder and the intercooler are not cooled, and the exhaust temperature of the compressor rises sharply. This not only causes the lubricating oil in the cylinder to lose lubrication performance, but also causes the moving parts to wear rapidly, and the lubricating oil is decomposed, and the volatile components in the oil are mixed with the air, causing accidents such as burning and explosion.
For large-scale quick-freezer compressor oil coolers, the water loss of the Wuxi Guanya LNEYA compressor will result in poor cooling of the lubricating oil and an increase in the temperature of the compressor lubricating oil. In this way, the viscosity of the lubricating oil is lowered, the lubricating performance is deteriorated, the wear of the moving parts is intensified, the life of the machine is reduced, the power consumption is increased, and the lubricating oil is decomposed, and the volatile components in the oil are mixed into the air, causing an accident.
Overheating of the compressor will affect the operation of the large-scale quick-freezer, so it is recommended to do the cooling work in order to run smoothly.
Verwandte Empfehlungen
-
Professionelle Einführung und Anwendung von Kühlwasserumlaufmaschinen
1577The cooling water machine (the chiller, also known as the chiller) is an air-cooled water circulation device that does not require a cold water tower. It is a compressor-cooled design that is designed for machines, scientific instruments, or produ...
Details anzeigen -
Buying Tips of Ultra Low Temperature Freezer
1615As for the industrial refrigerating treatment, the ultra low temperature freezer is indispensable. Let me tell you something about it!The ultra low temperature freezer of Wuxi Guanya Refrigeration technology co., Ltd is mainly used in industrial r...
Details anzeigen -
Chip test system analysis why chip test?
1804Functional failure means that a function point is not implemented. This is often caused by design. Usually, it is verified by simulation before the design stage, so usually a chip is designed and the simulation verification takes about 80% of the ...
Details anzeigen -
Entladungsvorgänge von Industriekühlern in Ammoniak-Kältesystemen
1601Der Gummischlauch, der zum Anschluss des Auslassventils verwendet wird, wird mit einem Ende in das Wasser des Wasserbehälters eingeführt. Wenn das Ammoniak im Mischgas zu Ammoniakflüssigkeit abgekühlt ist, gefriert der Boden des Luftabscheiders. Zu diesem Zeitpunkt, ...
Details anzeigen