Welche Wartungsarbeiten sind bei Glykol-Kaltwassersätzen im täglichen Betrieb erforderlich?
In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance.
Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
Verwandte Empfehlungen
-
Kühlungs-Simulationssystem für die Prüfung der extremen Leistung von Batteriepacks
1684Mit der Entwicklung der Technologie werden reine Elektrofahrzeuge immer häufiger, aber reine Elektrofahrzeuge sind schwierig, eine bessere Lösung in Bezug auf Reichweite, Ladegeschwindigkeit und Umweltverschmutzung nach Batterieabfall zu bekommen. Dies macht...
Details anzeigen -
Ultra-low temperature freezer power supply and electronic control instrument system description
1855Ultra-low temperature freezer needs to be tested after a long time of use. What should be paid attention to when the power supply and electronic control instrument system are inspected? Check the ultra-low temperature freezer power supply and the ...
Details anzeigen -
Precautions for the use of LNEYA chillers in industrial processes
17611. Installation (check the machine for damage, choose the right location for installation and maintenance) 2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the wor...
Details anzeigen -
Exhibition Preview | 2019 China International Automotive Testing Quality Monitoring Expo
1810Autumn is cool, the exhibition season is here again!For you to present Wuxi Guanya LNEYA exhibition information: We invite you to attend:2019 China International Automotive Testing and Quality Control ExpoExhibition time: September 24-26Exhibi...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant