Was sind die wichtigsten Punkte für die regelmäßige Wartung des Rückkühlers?
Recirculating chillers are used frequently in the industry, and the heat generating parts of various devices require recirculating chillers, so operating efficiency is very important.
During the running time of the recirculating chiller, it is necessary to frequently check whether the cooling water pipe connection is safe and firm. Whether the flow, temperature and pressure of the cooling water are appropriate, so as not to affect the cooling effect of the recirculating chiller if the water flow is too large or too small.

The operator also needs to set a time to check the circulating water position of the water tank on a specific date each year to avoid the water level drop without knowing it, resulting in insufficient circulating water supply, so regular inspections and replenishment of circulating water.
During the use of the recirculating chiller, in order to prevent the growth of microorganisms and other substances in the circulating water and affect the cooling effect of the recirculating chiller, it is necessary to pay attention to water quality issues. It is recommended to check the water quality problems regularly and to replace the water quality at least annually.
In addition, the compressor air-cooled filter and the cooling fan blades in the recirculating chiller should be cleaned regularly. It is recommended that they should be cleaned every 6 months. After the cleaning is completed, 1 to 2 drops of oil should be added to the recirculating chiller fan bearing.
In order to reduce the impact of the scale of the recirculating chiller on the flow and cooling capacity, the pipeline is cleaned every 5 years (every 2 years if the tap water is used for cooling) to reduce the generation of pipeline scale.
Verwandte Empfehlungen
-
Troubleshooting of refrigeration system failure of material aging test equipment at low temperature
1072Regular maintenance work for the material low temperature and high temperature aging test system, and troubleshooting of the refrigeration system is also very important. Here are a few tips. 1. Exhaust at double high pressure, heat dissipation ma...
Details anzeigen -
The ethylene glycol chiller solution is too cold and too hot
1042When the ethylene glycol chiller solutionis overheated and overcooled during operation, if you don't understand theseconditions well, you will not be able to operate the equipment well.The supercooling phenomenon of the solutionof the glycol ch...
Details anzeigen -
Routinewartungspunkte von speziellen Kühlgeräten für Laborgeräte
1089Industrielle Kühlaggregate für Laborgeräte werden vermehrt in der pharmazeutischen und chemischen Industrie eingesetzt und müssen daher mit Sorgfalt behandelt werden. Die tägliche Wartung des industriellen Kühlgeräts für Laborgeräte muss...
Details anzeigen -
Explanation Protection for Air Cooled Precision Chiller
1037The places where need air-cooled precision chiller indicate they have high demanding for operating accuracy. Therefore, the protection settings have to work out. Then, which kind of protection for air-cooled precision chiller should be done?Discha...
Details anzeigen