Operation Instructions of Heating Cooling Circulator
Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and realizing the refrigeration process. In the heating process of heating cooling circulator, heat is the process of heating with heat conducting oil to provide heat source, because the low temperature state is impossible to provide heat as the high temperature state.
Refrigeration cycle includes compression refrigeration cycle, absorption refrigeration cycle, adsorption refrigeration cycle, steam jet refrigeration cycle and semiconductor refrigeration cycle, etc. Heating cooling circulator of Wuxi Guanya mainly adopts compressor refrigeration cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of reverse Carnot cycle, so it can be regarded as reverse Brayton cycle. In engineering application, compressor can be piston type or impeller type. After entering the compressor, the air from the heating and refrigeration cycle equipment is adiabatically compressed, and the temperature rises above the ambient temperature. Then it enters the cooler and transfers the heat to the cooling water at a constant pressure, the temperature is equal to the ambient temperature. Then the expander is introduced to adiabatic expansion, and the temperature is further reduced to below the temperature of the heating and refrigeration cycle equipment. Then it enters the heating and refrigeration cycle equipment, which absorbs heat at constant pressure (the heat absorbed is called refrigeration capacity), and completes the cycle.
After the refrigerant is vaporized and absorbs heat from the Heiz-Kühl-Umwälzpumpe at constant pressure (at this time the working medium is usually dry saturated steam or near dry saturated steam), it enters the compressor to compress in adiabatic state, the temperature exceeds the ambient temperature, and then enters the condenser to heat the ambient medium at equal pressure. In the condenser, the superheated refrigerant vapor is first isobarically cooled to the saturated temperature corresponding to the current pressure, then continues isobaric (which is also isothermal) condensation to the saturated liquid state. It enters the throttle valve, adiabatic throttle at the throttle valve to reduce temperature and pressure to the wet saturated vapor state corresponding to the starting pressure of the cycle, and then enters the heating and refrigeration cycle equipment to gasify and absorb heat to complete the cycle.
Verwandte Empfehlungen
-
Precautions for safe use of heat transfer oil temperature control equipment
1588With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temp...
Details anzeigen -
Prospects for the development of electronic test thermal systems
1330For the modern society, energy conservation and emission reduction is also an important task. In the development of semiconductor, chip, integrated circuit and other industries, the electronic test thermal system can effectively test its temperatu...
Details anzeigen -
Mit diesen Punkten kann die Nutzungseffizienz der Ultra-Niedrigtemperatur-Kältemaschine effizienter sein
1650The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
Details anzeigen -
Umfassendes Testsystem für Automobilmotoren mit neuer Energie
1784When the LNEYA new energy vehicle motor integrated test system is running, the control panel settings are required. At the time of setting, if the user does not know how to use it, you can check the manual for use. The indicator of the new energy ...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant