Introduction To The Preparation Of Low Temperature Chiller’ Operation
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the Niedertemperaturkühler, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
Verwandte Empfehlungen
-
Where are the applications of the CO2 supercritical extraction cryogenic refrigeration unit?
1599With the continuous development of co2 supercritical extraction technology, co2 supercritical extraction cryogenic refrigeration devices have attracted the attention of many industries due to their own characteristics, and have been widely used in...
Details anzeigen -
Gebrauchsanweisung für das Sekundärkreislaufsystem für Wärmeträgeröl
1490The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation. LNEYA heat transfer oil secondary circul...
Details anzeigen -
How to avoid incorrect operation of heating and cooling thermostat?
1477When the user is running the heating and cooling thermostat, the operation needs to follow the instructions, so how to avoid inappropriate operations? Excellent design of hot and cold thermostat: The LNEYA heating and cooling thermostat has a mul...
Details anzeigen -
Battery module test equipment selection error description
1610Many battery module companies have certain misunderstandings about LNEYA's battery module test equipment. There are some errors in selecting the battery module test equipment model, so try to select the battery module test equipment. Avoid some mi...
Details anzeigen