How to use industrial water chiller to reduce environmental pollution
With the continuous development of chemical
and pharmaceutical industries, environmental pollution is put on the agenda
earlier. As an manufacturer of which is the industrial water chiller, I can say
that except for corresponding to the environmental protection theme, Our LNEYA
circulating water chillers use environmentally friendly materials and
Kühlmittel,increasing the efficiency constantly.
Industrial chiller units lower the
condensing temperature in the conditions of evaporating temperature, and increase
the vaporization point and reduce the condensation temperature as much as
possible when meeting the requirement of safety and manufacture, ensuring the
cooling water efficiency and enlarging the change of cooling tower.
I should tell you that for the sake of
ensuring the industrial water chiller to operate safely, the power dissipation
of a number of cold energies is smaller. It should consider the operating
situations of the water pump and cooling tower comprehensively while taking
this method into effect.
To prevent and reduce the pipe scaling of
industrial water chiller is for enhancing the heat transfer efficiency of the
condenser and evaporator. If the make-up water is treated badly, calcium
carbonate and magnesium carbonate produced by calcium bicarbonate and magnesium
bicarbonate through heating will precipitate on the pipes, decreasing the
heat-conducting property to have an impact on the heat exchange efficiency of
condenser and evaporator and increase the electric charge by a large margin for
chiller’s operation. Apart from using water treatment technology, that you can
apply the equipment for cleaning the pipes regularly, which can save the
electric quantity and at the same time level up cooling-water machine’s effect.
When centrifugal refrigeration machine’s
compressor is adjusted by the frequency converter of industrial water chiller
on account of revolving speed, the pressure will be raised as low-tension
refrigerant goes through hydroextractor. The faster the rotational speed is,
the higher the pressure is. In actual operation, the equipment works without a
full load. The centrifugal machine with fixed revolving speed operating in
small load will waste the energy.
When mastering the four points mentioned
above, I am sure the working efficiency will be improved better. It is
necessary to follow these steps so as to protect the environment!
Verwandte Empfehlungen
-
Wartung des Verflüssigers der Hoch- und Niedertemperatur-Umwälzanlage
1864Der Verflüssiger im Hoch- und Niedertemperaturkreislauf mit konstanter Temperatur ist eines der Zubehörteile im Kühlprozess, und seine Leistung ist sehr wichtig. LNEYA weist den Benutzer darauf hin, dass eine regelmäßige Wartung nach ...
Details anzeigen -
LNEYA’s 300,000 kcal air-cooled unit on air tightness
1715When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
Details anzeigen -
Umwelttechnische Beschreibung eines Kondensators für große industrielle Gefriergeräte
1693In der industriellen Kälteverarbeitung gehören große industrielle Gefrierschränke zu den am häufigsten verwendeten Geräten. Dabei ist der Kondensator eine der wichtigsten Komponenten, und seine Leistung ist sehr wichtig. Daher muss jeder bei der Auswahl noch verstehen,...
Details anzeigen -
Factors affecting the cooling capacity of the chiller of the chemical reactor cooling system
2180There are various types of chillers, such as air-cooled chillers, water-cooled chillers, etc. But no matter what the chiller is, there are some factors that affect the cooling capacity of the chiller. A cooler is an energy-saving device that is co...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant