Ultra-low temperature freezing manufacturer analyzes the cause of blockage in refrigeration system
With the continuous development of technology, ultra-low temperature refrigeration technology is also constantly developing, and manufacturers are also increasing. Of course, the technology of different manufacturers is different. Once the refrigeration system is blocked, it needs to be solved in time.
If the refrigeration system of the ultra-low temperature freezer is clogged, it is necessary to understand that the formation of the clogging fault in the refrigeration system is caused by excessive impurities in the refrigeration system. The impurities in the refrigeration system of the ultra-low temperature freezer are derived from dust and metal chips in the manufacturing process. When the inner wall surface of the oxide layer falls off; the inner and outer surfaces of the parts are not cleaned during the processing; the pipeline is not tightly sealed and dust enters the tube, and the refrigerator oil and the refrigerant contain impurities.
The clogging of the refrigeration system has a certain influence on the ultra-low temperature freezer, which causes the refrigerant to be unable to circulate, the compressor is continuously operated, the evaporator is not cold, the condenser is not hot, the compressor casing is not hot, and there is no airflow sound in the evaporator. The evaporator has a cold or cold feel, but it does not frost. When you touch the outer surface of the filter and capillary, it feels cool, has frost, and even forms a layer of hoarfrost.
If the cryogenic refrigerator refrigeration system is clogged, it is recommended to use a drying oven to heat and dry the components. The compressor, condenser, evaporator, capillary, and return air hose in the refrigerant system are removed from the refrigerator and placed in a drying oven. The inside is heated and dried, the temperature in the box is about 120 ° C, and the drying time is 4 hours. After being naturally cooled, the air is blown and dried one by one with nitrogen. Replace the new desiccant filter and then assemble and weld, pressurize and leak, vacuum, fill the refrigerant, test run and seal.
The ultra-low temperature freezer also uses a heating vacuum and a secondary vacuum to remove moisture from various components of the refrigeration system. The high-pressure nitrogen gas was used to blow out the dirt in the capillary tube, and the process tube was cut and the liquid was drained. After the capillary tube was unblocked, 100 ml of carbon tetrachloride was added for aeration cleaning. The cleaning of the condenser can be carried out with carbon tetrachloride on the pipe cleaning device. Then replace the dry filter, and then add nitrogen to leak, vacuum, and fill the refrigerant.
Wuxi Guanya LNEYA ultra-low temperature refrigeration technology manufacturers refrigeration technology using single-machine self-cascade refrigeration technology, its configuration also uses brand accessories configuration, so that the operation of ultra-low temperature freezer keeps running smoothly.
Verwandte Empfehlungen
-
Small desktop sealed chiller troubleshooting solution
1444Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
Details anzeigen -
Die Funktion Einführung von Heizung-Kühlung-Übersetzer
1581Die von Wuxi Guanya hergestellten Heiz- und Kühlthermostate der Serie HR können als Kälte- und Wärmequelle eingesetzt werden und haben einen breiten Einsatzbereich. Sie werden in der pharmazeutischen, chemischen, biologischen und anderen Industrien verwendet,...
Details anzeigen -
Temperaturkontrollsystem der Aufdampfbeschichtungsanlage - Kühlwassersystem
1718Der Hauptzweck der Aufdampfbeschichtungsanlage ist die Durchführung wissenschaftlicher Experimente und die Erforschung des Filmbildungsprozesses. Es besteht aus Quarzrohr Reaktionskammer, Hitzeschild Ofen Schrank, elektrische Steuerung, Vakuum ...
Details anzeigen -
The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
2041Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant