Die Sicherheit von Wärmeträgeröl in wassergekühlten Kältemaschinen
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
Verwandte Empfehlungen
-
Description of compressors in various high and low temperature cycle machine industry
1903In the pharmaceutical and chemical industry, the application of high and low temperature cycle machine is relatively common. LNEYA high and low temperature cycle machine compressors use Emerson, Taikang, Duling and other brand compressors, but the...
Details anzeigen -
Ethylene glycol refrigeration unit made a strong attack and created LNEYA brand in 12 years
1976Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...
Details anzeigen -
Was bedeuten die Fehlercodes von luftgekühlten Kältemaschinen?
1816Im Allgemeinen sieht man auf dem Bedienfeld des Geräts 2 Bereiche, nämlich den PV-Bereich und den SV-Bereich. Der erste Bereich zeigt die spezifische Temperatur an, der zweite dient zur Einstellung der Temperatur. Wenn eine Störung auftritt, zeigt PV die Anzahl der ...
Details anzeigen -
Anleitung zur Auswahl eines Temperaturregelsystems für Halbleiterkühlgeräte
2159Die Wahl des Temperaturregelsystems für die Halbleiterkühlung sollte auf der Grundlage der Kühllast und der zu berücksichtigenden Faktoren erfolgen. Für Kältesysteme mit langen Betriebsbedingungen mit niedriger Last Betrieb, ist es geeignet, mul...
Details anzeigen