Hochtemperatur-Silikonöl Kühlung und Heizung Zyklus Maschine Wartung Schritte
The mechanical wear of the high temperature silicone oil cooling and heating cycle machine is an important factor that directly affects the refrigeration capacity. It is necessary to record the operating parameters during use, often listen to the sound during the operation, and check the refrigerant and refrigerating oil. Troubleshoot based on this, regular maintenance and maintenance, so that when the high-temperature silicone oil cooling and heating cycle machine fails, the maintenance personnel can quickly find the problem and eliminate the fault by referring to the recorded parameters.
Maintenance steps:
1. Discharge the refrigerant in the industrial chilled system: the needle valve is kept on the suction side of the industrial explosion-proof low-temperature refrigerator, the three-way valve is connected to the needle valve, the operating valve is opened, and the inside of the refrigerator is cooled. All reagents in the industrial refrigerator system have been discharged;
2. Replace the faulty parts of the high-temperature silicone oil cooling and heating cycle machine: If you know which parts are faulty, please directly replace the faulty parts;
3. Nitrogen flushing and pressure test: Nitrogen is still injected through the needle valve on the suction side of the industrial high-temperature silicon oil cooling and heating cycle machine;
4. Vacuum: After the pressure test, the industrial refrigerator needs to be vacuum cleaned to ensure that there is no problem;
5. Refrigerant filling: There are two filling methods for the refrigerant in the high-temperature cooling and heating cycle machine, namely the low-pressure side filling method and the high-pressure side filling method;
6. Test run: After completing the above steps, please test run the high-temperature silicone oil cooling and heating cycle machine to ensure that there is no problem;
After completing the maintenance of the high-temperature silicone oil cooling and heating cycle machine and troubleshooting, the performance of the corresponding parts will be tested to ensure the reliable and stable operation of the equipment.
Verwandte Empfehlungen
-
The main purpose of the ethylene glycol chiller for the heating and cooling unit of the reactor
1832The glycol chiller is suitable forhigh-purity metal, rare substance purification, laboratory environmentsimulation, magnetron sputtering, vacuum coating and other industries. Largecryogenic pump units can provide a cooling environment for labor...
Details anzeigen -
Wie erwirbt man ein Temperaturprüfsystem für Leistungsmanagement-Chips?
1870Das Temperaturprüfsystem für Leistungsmanagement-Chips ist ein wichtiges Gerät, mit dem die Leistung und Zuverlässigkeit von Halbleiterchips in verschiedenen Temperaturumgebungen geprüft werden kann. Wenn Sie diese Art von Testausrüstung kaufen, müssen Sie...
Details anzeigen -
Betriebsanleitung für die Kältemaschine, ein Kreislaufsystem für die Temperierung von Laborprozessen
1723Das Wärmeträgermedium des Laborprozess-Temperaturregelkreislaufs verwendet Öl und Wasser. Das Wärmeträgermedium (Wärmeträgeröl oder Wasser), das in den Rohrleitungen zirkulieren muss, wird durch eine elektrische Heizung erwärmt...
Details anzeigen -
How to eliminate the failure of large thermal shock test chamber?
1533As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner. A large t...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant