Wann sollte man sich für ein TCU-Temperaturkontrollsystem entscheiden?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
Verwandte Empfehlungen
-
Was ist VCSEL im Chip Burn-in Test? Welche Auswirkung hat die Temperatur auf ihn?
1506Der vollständige Name von VCSEL ist Vertical-cavity Surface-emitting Laser, der chinesische Name ist Vertical Cavity Surface-Emitting Laser. Er ist eine Art von Halbleiterlaser. Halbleiterlaser sind Laser, die mit Hilfe der Halbleiterfertigungstechnik hergestellt werden...
Details anzeigen -
Lernen Sie die Leistung von LNEYA Industrial Freezer Accessories kennen
734Temperaturregler Der Temperaturregler dient zur Steuerung oder zum Schutz des Geräts. Wenn die Temperatur den eingestellten Wert erreicht, unterbricht der Schalter automatisch den Stromkreis (oder schaltet ihn ein). In unseren Produkten ist die Temperaturregelung oft...
Details anzeigen -
The Introductions of the Ultra Low Temperature Recirculating Chillers
1117The performances of ultra low temperature recirculating chillers are different because of their different compressors. Compared with piston compressor, the structure of screw-type compressor tends to be more precise, so when users need to select u...
Details anzeigen -
Failures of Heating Cooling Circulators
949The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
Details anzeigen