About high and low temperature cycle machine refrigerant selection instructions
In the operation of high and low temperature cycle machines, the presence of refrigerant is essential, and the environmentally friendly mixed refrigerant used by LNEYA is better in terms of performance.
The high and low temperature cycle machine has a higher critical temperature and can undergo a phase change at normal temperature or normal low temperature, which is a basic requirement for the refrigerant in the steam high and low temperature cycle machine. High and low temperature cycle refrigerant suitable for saturated vapor pressure. Do not lower the evaporation pressure below atmospheric pressure to prevent air from leaking into the refrigeration system. The condensing pressure should not be too high to avoid excessive increase of high and low temperature cycle machines and equipment. At the same time, the ratio of the condensing pressure to the evaporation pressure should not be too large, so that the gas temperature is too high at the end of the compression and the gas transmission coefficient of the compressor is lowered.
The refrigerant solidification temperature is low to prevent the refrigerant from solidifying at the evaporation temperature. The viscosity and density are small to reduce the flow resistance loss of the refrigeration system. The high-temperature cycle machine has a high thermal conductivity to increase the heat transfer coefficient of the heat exchanger and reduce the heat transfer area and metal material consumption.
The refrigerant adiabatic index is small, which can reduce the power consumption of the compression process. At the end of the compression, the gas temperature is not too high, and the liquid heat capacity is small. The loss of the throttling process can be reduced, and the thermal perfection of the cycle is as large as possible. It does not burn, does not explode, is non-toxic, does not corrode to metal, does not have chemical action with lubricating oil, does not decompose under high temperature and is harmless to human body.
There are many types of refrigerants for high and low temperature cycle machines. The refrigerants used by different manufacturers are different. It is recommended that users choose environmentally friendly refrigerants better, energy saving and environmental protection.
Verwandte Empfehlungen
-
Heat transfer oil cleaning instructions in the heat transfer oil secondary circulation system
1683The heat transfer oil secondary circulation system uses the heat transfer oil as the medium to carry out the refrigeration and heating temperature control. Then, when the user cleans the heat transfer oil in the heat transfer oil secondary circula...
Details anzeigen -
Qualitativ hochwertige flüssige Hoch- und Niedertemperatur-Aufprallschutzkammer
2181Wenn Kunden eine flüssige hohe und niedrige Temperatur Auswirkungen Umweltkammer zum Verkauf wählen, vor allem, müssen sie ein klares Verständnis für seine Verwendung und Eigenschaften haben.Funktionen von flüssigen hohen und niedrigen Temperatur Auswirkungen Umweltkammer...
Details anzeigen -
Wie geht man mit dem überschüssigen Kältemittel in 3p-Gefrierschränken um?
1724When the three freezers are being serviced, it is necessary to add refrigerant regularly, but the manufacturer of LNEYA reminds everyone that once the refrigerant is added excessively, it will cause a series of problems. According to the instructi...
Details anzeigen -
Small environmental test chamber compressor should pay attention after maintenance
1635In the centrifugal small-scale environmental test chamber, the suction recovery device is generally an independent system, and if necessary, the pipeline connected to the condenser and the evaporator can be closed for separate maintenance. After r...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant