Auswirkung und Lösung der Abgasübertemperatur von industriellen Kühlanlagen
Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today LNEYA will recommend a few solutions for you:
Increase cooling water flow and heat ventilation of water tank and water tower:
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.
Reduce the exhaust temperature of the refrigeration compressor directly:
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of compressor.
Verwandte Empfehlungen
-
Does hydrogen energy manufacturing require process chillers for cooling?
1325Process chillers are indeed needed in the hydrogen energy manufacturing process. Especially in the production of hydrogen, such as hydrogen production by water electrolysis, a lot of heat is generated in this process. The electrolyze...
Details anzeigen -
Das Motorkühlsystem testet die Auswirkungen der Verflüssigungstemperatur
1976Das Motorkühlsystem testet den Kondensator. Unter normalen Bedingungen ist die erste Hälfte des Wärmerohrs sehr heiß, und ihre Temperatur nimmt in der Leistungsbilanz langsam und allmählich ab. Die Wärmeempfindlichkeit der zweiten Hälfte des Hea...
Details anzeigen -
Wann sollte man sich für ein TCU-Temperaturkontrollsystem entscheiden?
1569Zunächst einmal muss man wissen, dass der Reaktionskessel in der Regel neben der chemischen Reaktion des Materials selbst auch die notwendige Temperaturregelung durchführen muss. Durch die Temperaturveränderung des zirkulierenden Mediums im Mantel ...
Details anzeigen -
How to remove ultra-low temperature refrigerator shell and tube condenser scale?
1725Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant