How is the refrigerant installed in the vocs condensing unit?
The vocs condensing equipment is LNEYA’s equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated?
For various refrigeration and heating equipment, generally there are many types of refrigerants, mainly freon, unsaturated hydrocarbon refrigerant, saturated hydrocarbon refrigerant, inorganic compound refrigerant, azeotropic mixture refrigeration. These kinds of agents, etc., generally use environmentally friendly R404 or R22 refrigerant, so you can rest assured when using, do not worry about refrigerant pollution.
In general, vocs condensing equipment generally has two methods when installing refrigerant. One is to use the compressor to remove the valve through hole and directly inject the refrigerant liquid into the system. This method is relatively fast and safe, and is more suitable for filling in the system when it is vacuumed and there is no refrigerant. This method uses the pressure difference and height difference between the refrigerant in the cylinder and the system to discharge into the refrigeration system. Once the filling is insufficient, it can be changed to the suction side. Once it is filled on the high pressure side, Be careful not to start the compressor to avoid accidents.
Another method is to fill the suction port of the compressor suction valve. When using this method, pay attention to the compressor of the vocs condensing device. When filling the liquid, remember to start the compressor and not inject the liquid refrigerant. In order to avoid liquid shock in the vocs condensing equipment. This method is suitable for situations where the system is insufficiently filled and needs to be added.
Need to know more to run vocs condensing equipment, LNEYA’s own vocs condensing equipment, welcome everyone to buy.
Verwandte Empfehlungen
-
What is the refrigerant of the recirculating chiller
1694Different industries have differentrequirements for the refrigeration temperature of the recirculation chiller, sothe selected refrigerant is also different. When choosing a recirculationchiller, it is also necessary to have a clear understandi...
Details anzeigen -
Wie führt man einen industriellen Niedertemperaturkältetest durch, um das bessere Unternehmen auszuwählen?
1633Unabhängig davon, welche Kältemaschinen zum Einsatz kommen, müssen wir uns ständig mit den relevanten Kenntnissen über industrielle Niedertemperaturkältemaschinen vertraut machen. Welcher Kaltwassersatz eines Unternehmens ist besser? Lassen Sie mich Ihnen sagen, um Ihnen zu helfen, die industrielle...
Details anzeigen -
Wie gehen isolierte Wärme-Kälte-Umwälzpumpen mit Ineffizienzen um?
1553Heat dissipation is a common problem that causes inefficiencies in isolated heating refrigeration circulators, and it is also a problem that can easily occur. Many isolated heating and refrigeration circulators will have similar problems, so how t...
Details anzeigen -
Analyse von häufigen Fehlern im Batterietestsystem für New Energy Vehicle Power
1443Wenn die neue Energie-Fahrzeug-Power-Batterie-Pack Lecks, die allgemeine Fehler Manifestation Modus: das Messgerät OK Licht nicht leuchtet, fordert das Messgerät, um das Stromnetz zu überprüfen, die Hochspannungs-System Leckage Fehler, trennen Sie die Batterie-Pack und die b...
Details anzeigen