No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers.
Which company’s low – temperature chiller is better? Let me tell you, in order to help you to use the industrial low temperature chillers, you have to know these related knowledge of test.
Temperature detection of inlet and outlet
When the industrial low temperature chiller is being used, the thermometer of the inlet and outlet of the system is checked through the control system of the unit half an hour after starting up, which can read the inlet temperature and outlet temperature of the industrial low-temperature chiller. Ensure that the temperature difference between inlet and outlet water is not too large, once it is too large, the water flow may be shown to be small, which may cause the normal operation of the industrial low-temperature chiller.
Water pressure detection of inlet and outlet pipes
It is necessary to test the outlet and inlet water pressure values of industrial low-temperature chillers, and then check the instructions to see how much water flow is under normal conditions to judge whether the refrigeration system is normal. Which company’s low – temperature chiller is better? Let me tell you. We can judge which section of the pipe resistance value is larger, and make the corresponding rectification plan from the line.
Detection of suction temperature of copper tube of compressor
When using industrial low – temperature chillers, after running for half an hour, If the suction temperature of the compressor is detected below 0 degrees, it indicates that the water flow in the heat exchanger does not reach a fixed value. It is easy to cause the drop of evaporation force, which may lead to the refrigerant still absorbing heat in the process of evaporator flowing to the compressor, resulting in the suction temperature of the compressor being lower than 0 degrees.
Current detection during pump operation
During operation, the industrial low – temperature chiller can compare the current in the water pump with the rated current of the chiller. In this way, it can judge whether the current is large or small and detect the operation status of the water system at any time.
These are the methods of testing which company’s industrial low -temperature chiller is better. I hope you can quickly find problems in the chiller when you check it.
Verwandte Empfehlungen
-
Notes on Purchasing Low Temperature Chamber
1499Welcome to buy our high quality low temperature chamber.,
Details anzeigen -
Wie erwirbt man ein Temperaturprüfsystem für Leistungsmanagement-Chips?
1870Das Temperaturprüfsystem für Leistungsmanagement-Chips ist ein wichtiges Gerät, mit dem die Leistung und Zuverlässigkeit von Halbleiterchips in verschiedenen Temperaturumgebungen geprüft werden kann. Wenn Sie diese Art von Testausrüstung kaufen, müssen Sie...
Details anzeigen -
Laboratory crystallization temperature control cooling and heating system
1304In the laboratory crystallization process, temperature controlled cooling and heating system is a crucial component used to precisely control the temperature of the crystallization solution, in order to achieve high purity, specific morpho...
Details anzeigen -
ISG/TM Motortest Kühlsystem Hochspannungsausfall und Behandlungsmaßnahmen
1946The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant