Kältetechnik Heizungsumwälzpumpe Liste Resonanz Fehlerbeschreibung
Refrigeration heating circulator leaderboard works:
When the temperature of the reactor, reactor, rotary evaporator, extraction equipment, etc. of the refrigeration heating circulator needs to be rapidly increased or lowered, the equipment can quickly reach the set temperature.
LNEYA’s refrigeration and heating circulator list adopts a fully enclosed circulation system to avoid high temperature oil mist odor and low temperature absorption of moisture, which ensures that the working environment will not have a pungent odor, and also avoids the heat transfer medium absorbing moisture. Viscous adhesion to the reactor wall results in poor heat transfer. The heating and cooling of the equipment can be quickly converted, and the medium used (heat-conducting oil) is the same medium, which improves the disadvantages of the two different instruments required for heating and cooling.
Fixing parts of the cooling and heating circulator list cause resonance reasons:
The professional manufacturer of the refrigeration and heating circulator list tells the enterprise that if the resonance is encountered, the cement foundation may be too light or the grouting is poor or the plane size is too small, causing the fan foundation to be out of contact with the foundation, the anchor bolts are loose, and the base connection is not strong. The foundation stiffness is not enough or the stiffness of the fan base or the volute is too low, the inlet and outlet pipes connected to the fan are unsupported and softly connected, the adjacent facilities are too close to the foundation of the fan, or the stiffness is too small. In general, professional high and low temperature manufacturers recommend that you can reinforce the foundation or re-grout, tighten the nut, strengthen its stiffness or add support and soft joints, and even increase the stiffness.
In fact, reliable manufacturers on the cooling and heating cycler list can provide good quality and reduce the occurrence of faults.
Verwandte Empfehlungen
-
How to eliminate the failure of large thermal shock test chamber?
1533As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner. A large t...
Details anzeigen -
ISG/TM Motortest Kühlsystem Hochspannungsausfall und Behandlungsmaßnahmen
1948The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Details anzeigen -
Kühler für 200L Destillationskessel
1235Die Kältemaschine für 200L Destillationskessel muss zwei Hauptfunktionen gleichzeitig erfüllen: Eine ist es, Methanoldampf zu kondensieren, und die andere ist es, das Material während des Reaktionsprozesses zu kühlen. ...
Details anzeigen -
Instructions for the use of temperature control equipment for isolation reactors
1335The reaction kettle is a commonly used reactor in pharmaceutical and chemical production. The temperature control equipment of the isolated reaction kettle is realized by controlling two doors, namely the heating water valve and the cooling water ...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant