100L high and low temperature thermostat installation instructions
The 100L high and low temperature thermostat uses coolant as the transmission medium to transfer the heat generated by other instruments or equipment that need to be cooled, and dissipate the heat to the outside of the equipment through the refrigeration system, so as to ensure that the equipment works within the normal temperature range. Between instruments and equipment, a closed medium circulation is formed by the pressure of the water pump in the device, and the temperature sensor detects the temperature of the medium to implement the control of the refrigerator.
The 100L high and low temperature thermostat is widely used in a variety of experimental equipment such as: rotary evaporator, x-ray diffractometer, lcp emission spectrometer, ICP mass spectrometer, graphite furnace atomic absorption spectrometer, fluorescence analyzer, electron microscope, production test equipment, CNC machine tools , Laser equipment, etc. This model is an integrated device. The condenser-compressor and evaporator-circulating water pump units are all installed in the same cabinet, and this type of unit is generally installed indoors.
The 100L high and low temperature thermostat should be installed in a laboratory with a good environment. The 100L high and low temperature integrated machine should be installed on a well-ventilated, dust-free and cool solid ground or a test bench to avoid droplets and steam, and avoid possible influx , Where there is stagnation, flammable gas leakage, and near equipment that generates high frequency.
Zusammenfassend
The 100L high and low temperature thermostat should avoid places where acidic solutions are frequently used, and places where special sprayers are frequently used. From the consideration of convenience and safety during maintenance and installation, the space between the indoor unit and obstacles should be ensured as much as possible.
Verwandte Empfehlungen
-
How to maintain stable performance of biopharmaceutical laboratory oil cooler?
8781. A suitable working environment to prevent various failures of the oil cooler in the biopharmaceutical laboratory needs to provide a better operating environment for the equipment. Keep the environment clean and tidy, reduce the impact of vario...
Details anzeigen -
Characteristics of Industrial Constant Temperature Recirculating Chiller
1391Points for attention in the use ofindustrial constant temperature recirculating chillerIndustrial constant temperature recirculatingchillers are widely used in pharmaceutical, chemical and laboratory. Next,let's introduce the characteristics...
Details anzeigen -
Effect of High Precision Semiconductor Constant Temperature Series Evaporator on Refrigeration
861The high-precision semiconductor constant temperature series of different models of the equipment, the choice of evaporation is also different, then, what effect does the heat exchanger have on the high-precision semiconductor constant temperature...
Details anzeigen -
Die Funktion Einführung von Heizung-Kühlung-Übersetzer
997Die von Wuxi Guanya hergestellten Heiz- und Kühlthermostate der Serie HR können als Kälte- und Wärmequelle eingesetzt werden und haben einen breiten Einsatzbereich. Sie werden in der pharmazeutischen, chemischen, biologischen und anderen Industrien verwendet,...
Details anzeigen