Where will the reactor be used? How about the reactor temperature control system?
Generally, non professionals should be confused about the reactor.
The reactor is composed of reactor body, reactor cover, jacket, agitator, transmission device, shaft seal device, support, etc. It is generally understood as a container with physical or chemical reactions. Through the structural design and parameter configuration of the container, the functions of heating and mixing, hydrolysis, neutralization, distillation, evaporation, crystallization, storage, hydrogenation, alkylation, polymerization, constant temperature reaction, cooling and low and high speed mixing required by the process can be realized.
The application scope and scenario of the reactor mainly include the following eight areas: 1. Food agriculture; 2. University test; 3. Biochemical pharmacy; 4. Gold refining industry; 5. Scientific experiments; 6. Bioengineering; 7. Industrial factory; 8. New material industry.
The temperature control of the reaction kettle is divided into two types: rising temperature and cooling temperature (depending on whether the inside is exothermic reaction or endothermic). Steam, molten salt or other heating media are used for heating, while cooling is generally cooling water or other media. Whether heating or cooling, heating or cooling media flow control is used, manually open and close the valve, or use automatic control to control heating The control valve of cooling medium regulates the flow to control.
The whole liquid circulation is a totally closed system.
1. Speed block for temperature rising and cooling, controlling chemical reaction system
2. The heat conduction medium will not absorb water vapor at low temperature
3. The heat conduction medium will not be oxidized, discolored, or browning
No oil mist is generated at high temperature.
4. Thermodynamic changes of the fast response system, whether it is a severe endothermic or exothermic reaction, will not have temperature control hysteresis.
5. A heat conduction medium can be used for low temperature and high temperature, and can be used in the temperature range of – 120 ℃ – 350 ℃.
Verwandte Empfehlungen
-
Knowledge sharing of high-power chiller pipeline cleaning
1378For many companies, due to the weak awareness of daily maintenance of high-power chillers, industrial high-power chillers have not been effectively maintained for a long time. If the industrial high-power chillers lacks the necessary maintenance, ...
Details anzeigen -
Detailed Description of Single-Stack Refrigeration Technology
1906With the continuous development of the times, ultra-low temperature refrigeration technology is also constantly developing. On the list of ultra low temperature freezers, Wuxi Guanya continues to advance in the refrigeration equipment market with ...
Details anzeigen -
Matters Needing Attention in Maintenance of Low Temperature Chamber
14362.The temperature and humidity of the low temperature chamber are the important factors affecting the performance of the instrument. It can cause the corrosion of mechanical parts, reduce the smoothness of metal mirror, and cause the error or perf...
Details anzeigen -
Häufige Fehler und Ursachenanalyse bei luftgekühlten Kühlern
1881Während des Einsatzes von luftgekühlten Kältemaschinen ist es unvermeidlich, dass einige allgemeine Fehler auftreten. Die Benutzer müssen die möglichen Fehlerursachen verstehen und rechtzeitig entsprechende Lösungen finden, um die Produktion und den Betrieb stabiler zu machen...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant