Where will the reactor be used? How about the reactor temperature control system?
Generally, non professionals should be confused about the reactor.
The reactor is composed of reactor body, reactor cover, jacket, agitator, transmission device, shaft seal device, support, etc. It is generally understood as a container with physical or chemical reactions. Through the structural design and parameter configuration of the container, the functions of heating and mixing, hydrolysis, neutralization, distillation, evaporation, crystallization, storage, hydrogenation, alkylation, polymerization, constant temperature reaction, cooling and low and high speed mixing required by the process can be realized.
The application scope and scenario of the reactor mainly include the following eight areas: 1. Food agriculture; 2. University test; 3. Biochemical pharmacy; 4. Gold refining industry; 5. Scientific experiments; 6. Bioengineering; 7. Industrial factory; 8. New material industry.
The temperature control of the reaction kettle is divided into two types: rising temperature and cooling temperature (depending on whether the inside is exothermic reaction or endothermic). Steam, molten salt or other heating media are used for heating, while cooling is generally cooling water or other media. Whether heating or cooling, heating or cooling media flow control is used, manually open and close the valve, or use automatic control to control heating The control valve of cooling medium regulates the flow to control.
The whole liquid circulation is a totally closed system.
1. Speed block for temperature rising and cooling, controlling chemical reaction system
2. The heat conduction medium will not absorb water vapor at low temperature
3. The heat conduction medium will not be oxidized, discolored, or browning
No oil mist is generated at high temperature.
4. Thermodynamic changes of the fast response system, whether it is a severe endothermic or exothermic reaction, will not have temperature control hysteresis.
5. A heat conduction medium can be used for low temperature and high temperature, and can be used in the temperature range of – 120 ℃ – 350 ℃.
Verwandte Empfehlungen
-
Hochdruckversagen eines Tiefkühlschranks aus rostfreiem Stahl
1242At the high speed of the stainless steel cryogenic refrigerator compressor, the temperature rises and the compressor generates high air pressure, which causes the high voltage protection relay to operate. The discharge pressure of the compressor r...
Details anzeigen -
Refrigeration Explanation for Screw Compressor of Low Temperature Chiller Circulator
1172Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the ...
Details anzeigen -
Precautions for the use of LNEYA chillers in industrial processes
11831. Installation (check the machine for damage, choose the right location for installation and maintenance) 2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the wor...
Details anzeigen -
Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
1084The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and ...
Details anzeigen