Solution to High and Low Pressure Fault of Water Cooled Chiller
The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of water-cooled chiller. The reason can be preliminarily identified as poor water quality, and corresponding impurities (leaves, weeds, etc.) enter the water distribution hole, which affects the heat dissipation of the cooling water tower. Next, I will introduce the reasons and solutions for the high and low pressure disadvantages of a water-cooled chiller.

Causes and solutions of high and low pressure disadvantages of water-cooled chiller:
In the application of water-cooled chiller, we often encounter high and low pressure alarm of chiller! In terms of high pressure, it is generally poor heat dissipation, which will lead to poor cooling effect of the chiller. For a long time, high pressure will also lead to high current and burn out the compressor. Generally, there is no cold coal or cold coal leakage in the low pressure alarm. The compressor will also be damaged if it works at low pressure for a long time.
Generally, water-cooled chillers have high and low pressure gauges, which are divided into high pressure and low pressure. In addition, industrial chillers are roughly divided into air-cooled chillers and water-cooled chillers: at present, the surface plate of industrial chillers on the market is divided into computer board and manual control board. High pressure and low pressure of computer board are well separated, but generally, the high and low pressure alarm lights of manual control board chillers are together, so it is not so easy to distinguish.
Therefore, you should first know whether the chiller you are using is an air-cooled chiller or a water-cooled chiller, whether it is a computer board or a manual control board, whether it is a high-pressure alarm or a low-pressure alarm. For the high-pressure alarm of the air-cooled chiller, you need to clean the cooling network, and for the low-pressure alarm, you need to check whether the cold coal leaks or the pressure gauge has no pressure, The high pressure alarm of water-cooled chiller requires cleaning the condenser. Low pressure alarm also depends on whether the pressure gauge has no pressure, so it is necessary to check the leakage, make up the deficiency and add cold coal.
Verwandte Empfehlungen
-
ISG/TM Motor Test Cooling System High Voltage Failure and Treatment Measures
1202The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Details anzeigen -
How to solve the frosting phenomenon of 50p freezer compressor?
101250p freezer is used in industrial cold treatment, but if the performance is not good, it may lead to industrial work, especially if it is faulty, it is more difficult to solve. Therefore, it is better to understand the various faults of the 50p re...
Details anzeigen -
Description of refrigeration principle in semiconductor wafer temperature control
1247In the operation of the semiconductor wafer temperature control refrigeration system, a state transition of a certain working fluid is used, and the necessary heat Q0 is extracted from the heat source of a lower temperature, and the heat Qk is sen...
Details anzeigen -
Umgang mit dem Störungsalarm der Rückkühleinrichtung
897Was ist zu tun, wenn während des Betriebs der Rückkühleranlage eine Störung und ein Alarm auftritt? Um die Produktion zu gewährleisten, müssen solche Probleme schnell behoben werden. Wir müssen zunächst die Ursachen von Ausfällen und Alarmen verstehen und verschiedene...
Details anzeigen