SR & ZLF series TCU Reactor Cooling Heating Temperature Control System
ANWENDUNGEN
TCU temperature control system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquid - the "primary system") infrastructure to integrate into a single fluid system or secondary loop used to control the temperature of process equipment. It can achieve dynamic temperature control from -120℃ to 300℃.
Produktmerkmale
Produkt-Parameter
Modell | ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH |
ZLF-50N ZLF-50NS ZLF-50NH ZLF-50NSH |
ZLF-80N ZLF-80NS ZLF-80NH ZLF-80NSH |
ZLF-125N ZLF-125NS ZLF-125NH ZLF-125NSH |
ZLF-200N ZLF-200NS ZLF-200NH ZLF-200NSH |
Temperaturbereich | -45-250 (the max Temp is determined by the heat and cold source supplied by the user)-40-135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
ZLF-N | Die Hauptkältequelle bzw. Hauptwärmequelle wird verwendet, um den Durchfluss des Systems durch ein proportionales Regelungssystem zu regulieren und die Wärme der Einspannung des Reaktionsbehälters zu steuern, und eine Reihe von Wärmetauschern zum Heizen oder Kühlen wird gesteuert oder gekühlt. | ||||
ZLF-NS | Besides ZLF-N function, add one set heater used to reduce high temp | ||||
ZLF-NH | Besides ZLF-N function, add electrical heating function | ||||
ZLF-NSH | Neben der ZLF- N Funktion gibt es einen Heizsatz zur Reduzierung der hohen Temperaturen und eine elektrische Heizfunktion. | ||||
Fläche des Wärmetauschers | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
Kontrollmodus | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
Kommunikationsprotokoll | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
Auswahl der Temperaturregelung | Prozess-Temperaturkontrolle | ||||
Rückmeldung zur Temperatur | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | Rückmeldung des Rohstoffprozesses: PT100 oder 4~20mA oder Kommunikation gegeben | ||||
Temp accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Umwälzpumpe | 150L/min 2.5BAR | 200L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | 750L/min 2.5BAR |
Eingabe und Anzeige | 7-Zoll-Farb-Touchscreen, Temperaturkurvenanzeige | ||||
Schutz der Sicherheit | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
Ventilstück ausführen | Proportional control valve control signal 4-20mA | ||||
Material des Gehäuses | SUS304 | ||||
Größe der Verbindung | DN40 | DN40 | DN50 | DN65 | DN80 |
Abmessung cm | 150*120*185 | 180*120*210 | 180*120*210 | 225*120*240 | 225*120*240 |
Power AC380V 50HZ | 2.3kW | 3,5 kW | 4,5 kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | Cold rolled sheet (REL7035) |
Modell | SR-35N SR-35NS SR-35NH SR-35NSH |
SR-50N SR-50NS SR-50NH SR-50NSH |
SR-80N SR-80NS SR-80NH SR-80NSH |
SR-125N SR-125NS SR-125NH SR-125NSH |
SR-200N SR-200NS SR-200NH SR-200NSH |
Temperaturbereich | -120~250 (the max. Temp is determined by the heat and cold source supplied by the user)-40~135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
SR-N | A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank |
||||
SR-NS | Besides SR- N function, add one set heater used to reduce high temp | ||||
SR-NH | Besides SR- N function, add electrical heating function | ||||
SR-NSH | Besides SR- N function, add one set heater used to reduce high temp and electrical heating function | ||||
Ausdehnungsgefäß | 100L | 200L | 280L | 390L | 500L |
Fläche des Wärmetauschers | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
Kontrollmodus | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
Kommunikationsprotokoll | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
Auswahl der Temperaturregelung | Prozess-Temperaturkontrolle | ||||
Rückmeldung zur Temperatur | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | Rückmeldung des Rohstoffprozesses: PT100 oder 4~20mA oder Kommunikation gegeben | ||||
Temp accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Umwälzpumpe | 200L/min 2.5BAR | 250L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | 750L/min 2.5BAR |
Eingabe und Anzeige | 7-Zoll-Farb-Touchscreen, Temperaturkurvenanzeige | ||||
Schutz der Sicherheit | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
Ventilstück ausführen | Proportional control valve control signal 4-20mA | ||||
Material des Gehäuses | SUS304 | ||||
Größe der Verbindung | DN40 | DN40 | DN50 | DN65 | DN80 |
Abmessung cm | 150*120*185 | 180*140*240 | 180*140*240 | 220*180*265 | 220*180*265 |
Power AC380V 50HZ | 2.3kW | 3,5 kW | 4,5 kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | Cold rolled sheet (REL7035) |
FUNKTIONSPRINZIP
(Kontrolle der Temperatur des Reaktormaterials)
- Die Methode der Änderung des Regelungs-Sollwerts kann auf die Systemverzögerung im Prozess so schnell wie möglich reagieren und ein geringeres Überschwingen des Systems erreichen. Die Regelung besteht aus zwei Gruppen von PID-Regelkreisen, dem Haupt- und dem Nebenregelkreis. Der Regelausgang des Hauptkreises wird als Sollwert für den Nebenkreis verwendet. Durch die Regelung des Temperaturänderungsgradienten auf diese Weise wird die Temperaturregelgenauigkeit des Systems gewährleistet.
- Der speziell entwickelte Hystereseprädiktor erzeugt ein dynamisches Signal yc(t) anstelle der Prozessgröße y(t) als Rückkopplungssignal. Generieren Sie ein e(t)-Signal für den Regler, so dass der Regler vorhersagt, dass der Regelvorgang keine große Verzögerung hat.

FÜR DIE TEMPERATURKONTROLLE VON REAKTORSYSTEMEN
Ein Host steuert 5~60 verschiedene Reaktoren
Berührungsloses Temperaturkontrollsystem im Mantel des Reaktionsgefäßes
Jeder Reaktor wird unabhängig gesteuert und beeinflusst sich nicht gegenseitig





Warum sollten Sie sich für lneya als Ihren Lieferanten für Temperaturkontrolle entscheiden?
Jahre der Erfahrung
Zufriedene Kunden
m² Produktionsfläche
Patentierte Technologien
Besuch der LNEYA-Fabrik
Kontaktieren Sie uns
Schicken Sie uns Ihre Anfrage und wir werden Sie innerhalb von 24 Stunden kontaktieren.
Produkte empfehlen