Summary of Maintenance Items of Glycol Chiller
During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.

Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
Verwandte Empfehlungen
-
Installation and maintenance of industrial water chiller
948As a industrial temperature control device,industrial water chiller is often in 24-hour operation. Therefore, it is veryimportant to choose a industrial chiller with good performance. Wuxi GuanyaRefrigeration Technology Co., Ltd. specializes in...
Details anzeigen -
What should you pay attention to when installing a DC charging pile cooling system?
924pay attention to when installing a DC charging pile cooling system
Details anzeigen -
Kleiner Heiß- und Kälteschock-Prüfkasten Gebrauchsanweisung
1044Kleine Thermoschock-Prüfkammer ist nicht-explosionsgeschützt Produkt (explosionsgeschützt muss angepasst werden), verwenden Sie es bitte nicht in der Umgebung mit brennbaren oder explosiven Gas. Um zu vermeiden, kleine thermische Schock, die Test-Box ist defekt, bitte...
Details anzeigen -
Es gibt in der Regel drei Möglichkeiten, die Temperatur von Laborreaktoren zu kontrollieren
9051. Manuelle Steuerung: Manuelle Bedienung des Drehknopfes an der Vorderseite des Reaktorsteuergeräts.2. Steuerung über PC: Der PC und der Regler sind über ein Netzwerkkabel verbunden, und die Bedienung erfolgt über den PC.3. Gesteuert durch Thermostat: Silikonöl...
Details anzeigen