What is the refrigerant of circulating water cooling equipment?
Different industries require different refrigeration temperatures for circulating water cooling equipment, so the selected refrigerants are also different. When choosing circulating water cooling equipment, you also need a clear understanding of the refrigerant.
Choose the corresponding refrigerant according to different equipment models:
All users who are engaged in the refrigeration industry must have a clear understanding of refrigerants. The types of refrigerants used in different temperature ranges are different. Generally speaking, the main types of refrigerants are: R12, R134, R600, R152/R22, R410A, R404, R23, etc. In the past, many manufacturers used Freon as a refrigerant, but today with the continuous development of environmental protection, the LNYEA circulating water cooling equipment has abandoned this environmentally friendly refrigerant and used environmentally friendly refrigerants such as R404, R23, and LNEYA mixed refrigerants. Choose the corresponding refrigerant for different equipment models.

When selecting a refrigerant, a comprehensive technical analysis should be carried out according to the specific situation:
Refrigerant is also called refrigerating medium, commonly known as refrigerant in some areas in the south. It is a working substance that continuously circulates in the refrigeration system and realizes refrigeration through its own state changes. The refrigerant absorbs the heat of the cooling medium (water or air, etc.) in the evaporator and vaporizes, and transfers the heat to the surrounding air or water in the condenser to condense. The selection of refrigerant is a more complicated technical and economic issue, and there are many factors that need to be considered. When selecting, a comprehensive technical analysis should be carried out according to the specific situation.
The environmentally friendly refrigerant of circulating water cooling equipment is different from Freon refrigerant. The big advantage is that its potential to destroy the ozone layer is zero, which can meet environmental protection requirements. At the moment when the theme of environmental protection is developing, it is very much in line with the development theme of the great era. On the other hand, refrigerants have small molecules, light molecular weights, strong permeability, and are very easy to absorb water and are not compatible with mineral oil. Therefore, the amount of refrigerant has higher requirements for the cleanliness of circulating water refrigeration equipment. Therefore, LNEYA adopts fully enclosed circulating pipelines to reduce the occurrence of refrigerant leakage, improve the operating efficiency of circulating water cooling equipment, and reduce enterprise costs.
There is still an important maintenance and support problem in the use and promotion of circulating water cooling equipment refrigerants. Due to the lag in the market, not only the dedicated refrigerants, refrigerating oil, lubricating oil, filter drier and compressor parts are less and expensive, but also the maintenance equipment and process requirements are also very high. The fully enclosed circulation pipeline used by LNEYA, The accessories are all brand, with better quality and lower failure rate.
If you purchase LNEYA related equipment, you can contact your sales engineer for after-sales consultation about the addition and use of refrigerants, our contact email sales@lneya.com
Verwandte Empfehlungen
-
Effect Of Humidity On Laboratory Chillers
1011The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance...
Details anzeigen -
The significance of temperature in IC testing
1474Every integrated circuit (IC) goes through two type of tests before it can be sold and used to build a product: the first is called a wafer test; the second is called final test. With the improvement of integrated circuit electrical test technolog...
Details anzeigen -
Die Unterscheidung und Anwendung von Heizungs- und Kühlungsumwälzpumpen
978Before discussing how to choose the right brand of heating cooling circulator, we need to know the definition and application of heating and cooling circulator. Definition: thermostatic waterbath is also called the thermostatic water tank, constan...
Details anzeigen -
Test of working temperature of electric vehicle power battery
991The normal working temperaturerange of power batteries for electric vehicles is -30 ~ 52 ° C, and the workingtemperature range is -46 ~ 66 ° C, which is difficult to achieve with existingpower batteries. Although local warming measures can be u...
Details anzeigen