Vorsichtsmaßnahmen für den Betrieb von Ethylenglykol-Niedrigtemperaturkühlern bei minus 30 Grad
The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly, it will cause a short service life.
Refrigerant leakage will not only affect the refrigeration efficiency of the minus 30 degree ethylene glycol utra-low temperature chiller, but also may affect the health of the personnel entering and leaving the equipment room due to refrigerant leakage, so the refrigerant leakage problem must be paid attention to.
Under normal circumstances, the refrigerant is not a consumable item, so it will not be missing frequently. If it is frequently or suddenly missing, it is recommended to check whether the refrigerant of the minus 30 degree ethylene glycol utra-low temperature chiller has leakage problems. If there is a leakage problem, it should be timely Find the leakage point and make up for the leakage, or replace the relevant refrigerant pipelines and connectors. If necessary, forced ventilation should also be performed.
The second is the load. To put it bluntly, it is not just the load of the compressor. The compressor must be coordinated with the machinery including the condenser, evaporator, expansion valve, etc. to be able to normally cool. In addition, there are water pumps and water towers or air-cooled utra-low temperature chiller. Fan systems, etc., these are compatible with each other. If the load of the utra-low temperature chiller exceeds the standard, it will not just be that the compressor is not enough, and all other parts and components will have the problem of excessive pressure! Larger loads, or exceeding the rated load, will cause overload and will affect more serious problems, including a series of problems such as decreased cooling efficiency, increased noise, increased vibration amplitude, excessive consumption of electrical resources, reduced life, etc. requires attention!
It can be said that the parameters related to temperature and pressure are important parameters of the minus 30 degree ethylene glycol utra-low temperature chiller. Enterprises should pay attention to the parameters related to the temperature and pressure of the equipment, and solve problems in a timely manner. In the process of use, we also need to pay attention to its maintenance and use instructions. Lneya provides minus 30 degrees ethylene glycol utra-low temperature chiller equipment to provide users with professional after-sales service.
Verwandte Empfehlungen
-
Fully closed cycle high viscosity fluid refrigeration heating flow control system
915Application:1. The tested object is connected to a test platform adapter.2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and co...
Details anzeigen -
Notwendigkeit der Temperaturkontrolle bei der fraktionierten Destillation der Destillation
959In der pharmazeutischen und chemischen Industrie laufen viele chemische Reaktionen ab, und mit der kontinuierlichen Entwicklung der pharmazeutischen und chemischen Industrie besteht ein großer Bedarf an solchen Instrumenten. Die traditionellen offenen Kühl- und Heizkon...
Details anzeigen -
Efficient operation of high and low temperature integrated machine
1155To ensure more efficient operation of the high and low temperature integrated machine, you should select the appropriate type of equipment and solve the problem in time. The selection of high and low temperature integrated machines requires some p...
Details anzeigen -
Heating and cooling cycle machine maintenance boot operation instructions
1141When users choose the heating and cooling cycle machine, they often have to choose the right conditions for their own work, and their knowledge of maintenance and start-up also needs our attention. After the installation of the heating and cooling...
Details anzeigen