Closed cycle heating system temperature deviation description
If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time.
In the steady state, the closed loop heating system displays the difference between the average value of the temperature and the average measured temperature at the center point of the workspace. (Note: The average display temperature here refers to the average display temperature of the temperature control instrument of the device). In the closed state of the closed circulation heating system (chamber), the measurement points of the working space are measured for the upper and lower deviations of the high temperature and the MIN temperature from the nominal temperature within a prescribed time. The object of the closed cycle heating system is that the temperature control instrument of the device displays the average temperature and evaluates the deviation from the reference point. Obviously, this has nothing to do with temperature uniformity. The closed-loop heating system temperature deviation index is easy to implement because it only evaluates the temperature average of the equipment temperature control meter.
LNEYA closed-loop heating system is dynamic constant temperature control of cold and heat source in high pressure reactor, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, and constant temperature of microchannel reactor Control; small thermostatic control system, temperature control of steaming system, low temperature and high temperature aging test of materials, combined chemical source cold source heat source constant temperature control, semiconductor equipment cooling and heating, vacuum chamber cooling and heating constant temperature control. The closed-loop heating system adopts a fully closed pipeline design and uses a high-efficiency plate heat exchanger to reduce the demand for thermal fluid while improving the heat utilization rate of the system and achieving rapid rise and fall temperatures. The heat-conducting medium is in a closed system with an expansion vessel. The heat-conducting medium in the expansion vessel does not participate in the circulation. Whether it is high temperature or low temperature, the temperature of the expansion tank is normal temperature to 60 degrees, which can reduce the absorption and evaporation of the heat-conducting medium during operation. risk.
The temperature deviation of the closed loop heating system is related to its temperature accuracy. The temperature accuracy of different closed loop heating systems is related to the performance of the system. Therefore, users should know how to understand the closed loop heating system at the beginning. Temperature control accuracy. (This article is from the source network, if there is any infringement, please contact LNEYA to delete, thank you.)
Verwandte Empfehlungen
-
Application of refrigeration and heating temperature control system in chemical synthesis
865chemical synthesis cooling heating system temperature control unit
Details anzeigen -
Analysis of Advantages and Disadvantages of Screw Water Chiller
1240Compared with other types of chillers, the overall energy consumption of high-quality screw water chiller is relatively small. Because the production technology of screw water chiller is more advanced and less energy is used, the equipment can qui...
Details anzeigen -
How to use high and low temperature circulation equipment in extraction and separation?
862With the continuous development of science and technology, high and low temperature cycle industrial temperature control equipment plays an important role in many fields, especially in the field of extraction and separation. This article wil...
Details anzeigen -
Drei häufige Ausfälle von luftgekühlten Schraubenkühlern
12881. Communication Failure: Computer-Controller steuert verschiedene Module durch Telekommunikationsleitungen und insgesamt Interface-Board, so dass die Hauptursache für die Kommunikation Fehler ist schlechter Kontakt oder Bruch der Kommunikationsleitungen, insbesondere die Schnittstelle oxida...
Details anzeigen