Wie lässt sich das Problem der Verdichtergeräusche in industriellen Niedertemperaturkühlern lösen?
In industrial Niedertemperaturkühler, compressor operation will produce noise, but only the
difference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?
Generally speaking, compressor noise must first understand the causes of its noise, in order to better deal with. The main reasons are: the compressor is not fixed well; compressor quality problems; compressor load is too large; compressor power supply is abnormal, running time is too long and other reasons. Understanding these reasons and solutions can make better use of industrial Niedertemperaturkühler compressors.
For the industrial Niedertemperaturkühler that have just started to use, if the noise is too big, it may be caused by the compressor not fixed properly when it is assembled. The fixing of the industrial Niedertemperaturkühler is fixed on the chiller bracket by the compressor foot. It must be fixed properly to ensure the normal operation noise of the compressor of the industrial cryogenic water chillers.
If it is not the fixed problem of compressor, it may be the compressor quality problem of industrial Niedertemperaturkühler. In the production of industrial Niedertemperaturkühler, Wuxi Guanya adopts brand compressor, which guarantees a little more quality.
If it is not fixed and quality problems, it may also be that the compressor load is too large, which will also restrict the operation of the compressor. The compressor load is too large is the larger reason for the compressor running noise. When the load rate exceeds 80%, there will be various problems.
If the power supply of industrial Niedertemperaturkühler is not normal, if the current and voltage are not working properly, noise will be produced. Only the normal current can ensure the normal operation of the compressor of industrial Niedertemperaturkühler.
Another point is that the long running time of industrial Niedertemperaturkühler will also affect the life of their compressors. The wear and tear of internal bearings or axle boxes of industrial Niedertemperaturkühler will cause greater noise of compressors. It is suggested that the compressors should be replaced or maintained.
Industrial Niedertemperaturkühler is widely used in industry, so the above failures should be solved in time to avoid affecting the production process of users.
Verwandte Empfehlungen
-
Einschlägige Kenntnisse über Reaktorkälteanlagen
928Die Reaktorkühlanlage ist eine Art von Wasserkühlanlage, die eine Art von Kühlwasseranlage ist, die eine konstante Temperatur, einen konstanten Durchfluss und einen konstanten Druck liefern kann. Das Funktionsprinzip der Reaktorkühleinrichtung...
Details anzeigen -
Analysis of the environmental requirements of the -20 °C freezer
1045Due to the difference in ambient temperature, there are certain requirements for the freezer. Today LNEYA came to tell you how the ambient temperature is good for the -20 °C freezer. Now there are many types of freezer boxes: hot and cold temperat...
Details anzeigen -
How to maintain the lubrication system of water-cooled chillers
935Medium-sized water cooled chiller,refrigeration temperature range from -80 ℃~ -30℃, safe,reliable, rapid cooling for the liquid, widely used in petrochemical, medical,pharmaceutical, biochemical and freeze-dried, military and other high-tech in...
Details anzeigen -
Energy Conservation is Crucial for Developing Ultra Low Temperature Recirculating Chillers
2198With the continuous development of chemical, refrigeration and pharmaceutical industries, environmental pollution is put on the agenda earlier. As an editor of which is the industrial chiller, I can say that except for corresponding to the environ...
Details anzeigen