Die Beziehung zwischen dem Preis der VCS-Adsorptionskondensationsanlage und der Konfiguration
The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the superheat is too large. The specific volume increases, the cooling capacity decreases, and the relative power consumption increases. The Bucher compressor comes to the frost, quickly closes the small suction valve, sharply reduces the amount of cooling, and relatively increases the power consumption.
As the evaporation temperature of the vocs adsorption condensing equipment decreases, the compression ratio of the BITZER compressor increases, and the energy consumption per unit of cooling capacity increases. When the evaporation temperature is lowered by 1 ° C, it consumes 3% to 4% more. Therefore, the evaporation temperature difference is reduced as much as possible, and the evaporation temperature is increased, which not only saves power consumption, but also improves the relative humidity of the cold room.
During the cooling process, the condensing temperature increases, the compression ratio of the compressor increases, and the energy consumption per unit of cooling capacity increases. If the heat exchange surface of the condenser and the evaporator is covered with an oil layer, the condensation temperature rises and the evaporation temperature decreases, resulting in a decrease in the amount of cooling and an increase in power consumption.
When the scale of the wall of the condenser of the condensing device of the condensing device reaches 1.5 mm, the condensation temperature rises by 2.8 ° C than the temperature before the fouling, and the power consumption increases by 9.7. The vocs adsorption condensing device evaporator surface is covered with a layer of frost, which reduces the heat transfer coefficient. Especially when the outer surface of the finned tube is frosted, it not only increases the heat transfer resistance but also makes the air flow between the fins difficult. Reduce the heat transfer coefficient and heat dissipation area of the exterior. When the indoor temperature is lower than 0 °C, when the temperature difference between the two sides of the evaporator tube group is 10 °C, the heat transfer coefficient of the evaporator after working for one month is about 70 before frosting.
The price of vocs adsorption condensing equipment is still appropriate depending on the configuration. Wuxi Guanya (LNEYA) has been carefully developed and achieved satisfactory results.

Verwandte Empfehlungen
-
Collocation Requirements For Lab Water Chiller
1146The lab water chiller is a relatively advanced cryopreservation equipment, which is suitable for blood stations, hospitals, health and epidemic prevention systems, scientific research institutes, electronic industry, chemical medicine, biological ...
Details anzeigen -
Wissensaustausch über Auswahl und Wartung von Kühlern
1131Kältemaschinen können in vielen Industriezweigen eingesetzt werden, aber wer ist der bessere Hersteller von Kältemaschinen für niedrige Temperaturen unter den Top-Kältemaschinenherstellern? Die Wahl des eigenen Modells und die Wartung sind auch sehr wichtig. Weiter, sehen Sie mit mir. 1. Bereich der...
Details anzeigen -
Theorie des Eisflusses, Eiswasserqualität, Durchfluss und Druck der Eiswassermaschine
846Die Enthärtung des Wassers ist ebenfalls ein wichtiges Problem bei der Verwendung von Kältemaschinen, und auch der pH-Wert des Wassers muss ständig überwacht werden. Der optimale pH-Wert sollte bei 7 liegen. Ein pH-Wert von mehr als 7 führt zu starker Korrosion...
Details anzeigen -
Wie wird die statische Elektrizität in der Ultra-Niedrigtemperatur-Prüfkammer kontrolliert?
1198Um die statische Qualität der Ultra-Tieftemperatur-Prüfkammer zu kontrollieren, muss die Ultra-Tieftemperatur-Prüfkammer die statische Elektrizität besser kontrollieren. Wie kontrolliert die LNEYA-Ultra-Niedrigtemperatur-Prüfkammer die statische Elektrizität...
Details anzeigen