Tips for Leakage Detection of Low Temperature Freezer
Soaking leakage detection
The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharged, like all kinds of relays and electrical control device. Taking advantage of warm water during the bubble test, because its surface tension is smaller than cold water, forming bubbles more easily. As an editor of Low Temperature Freezer, I want to tell you that the leakage point will be discovered simply if accompanied by intense light source. After the completion of soaking leakage detection, the surface ought to be dried with compressed air, preventing the metal from corrosion.
Halide torch and its leakage detection
These are the specialized devices for detecting the Freon freezer unit system. When Freon refrigerating fluid encounters hot cooper parts, different colored flames will be casted for F2, C12 and Br contain the elements of halogen, helping find out the leaking point.
Vacuum leak test
When freezer unit system passes the pressure leakage detection, it should also go through the vacuum leak test since some pasts exist one-way leaker. Only pressure and vacuum leakage detection both conform to the standard can the leakproofness of cooling system can be ensured. Besides, the system is evacuated, so can water at the same time , esped dcially the Freon system. Therefore, evacuation and desiccation play essential roles in debugging the unit.
Should the uses for low temperature freezer be understood, the users will have a better try! Visit LNEYA to know more about low temperature freezer price.
Verwandte Empfehlungen
-
Cooling and shrinking assembly freezer for metal parts and common assembly methods in the industry
1539In the cold shrink production of copper sleeves, bearings, etc., quick-freezing cryogenic boxes are widely used in mechanical assembly. Copper sleeve cooling shrink assembly cabinet variable temperature assembly method is to heat the hole or cool ...
Details anzeigen -
Inbetriebnahme von Kaltwasserkreislaufanlagen für Chemieunternehmen
1023After completing the installation of circulating water chillers in chemical enterprises, certain debugging needs to be carried out for industrial chemical circulating water chillers in the early stage of operation. Only through careful debug...
Details anzeigen -
Wie lässt sich die Ausfallrate des Wasserkühlungssystems des neuen Energiemotortests verringern?
998Neue Energie Motor Test Wasserkühlung System muss darauf achten, während der Nutzung, egal wie gut Ausrüstung für eine lange Zeit verwendet wird, einige Probleme mehr oder weniger auftreten. Also, wie können wir die Ausfallrate der Ausrüstung während des Gebrauchs zu minimieren?
Details anzeigen -
Cooling system of liquid-cooled energy storage cabinet-chiller
1139With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well...
Details anzeigen