Performance Characteristics of 30 HP Water Cooled Chiller
The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for cooling, which has some requirements for the environment: for example, ventilation, humidity and temperature cannot be higher than 40 ℃, air pH value, etc.

Performance characteristics of 30p water-cooled industrial chiller:
1. The primary effect filter is set inside to ensure the heat exchange effect of the heat exchanger and prolong the service life of the heat exchanger.
2. Wide operating range, high temperature control accuracy and energy consumption saving.
3. Special microcomputer automatic control, easier operation.
4. Independent working circuit, energy saving and high efficiency.
5. Shell and tube evaporation heat exchanger is adopted, which has high efficiency, good stability, convenient maintenance and simple operation.
6. The protection function is complete, safe, reliable and durable.
7. Continuous capacity control can effectively improve the energy efficiency ratio of the unit and reduce the operation cost.
8. The product has complete specifications and wide selection range, which is suitable for all kinds of comfortable and process places.
9. Compact design, small volume, light weight, small floor area and small installation and maintenance space.
10. During operation, the load can be adjusted according to the load, and the efficiency of partial load operation is higher.
The industrial chillers independently developed and produced by our LNEYA not only have 30HP, but also have more choices. Different working conditions require different models. If you have questions or purchasing needs, please contact us at sales@lneya.com.
Verwandte Empfehlungen
-
5L Glasreaktor Thermoöl-Heizsystem
716Der 5L-Glasreaktor ist ein gängiges Laborgerät, das für verschiedene chemische Reaktionen verwendet wird. Um sicherzustellen, dass die Reaktion bei der erforderlichen Temperatur abläuft, ist es in der Regel erforderlich, ihn mit einem Heizsystem auszustatten. Thermoöl (ein...
Details anzeigen -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
1071The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
Details anzeigen -
ISG/TM Motor Test Cooling System High Voltage Failure and Treatment Measures
1200The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Details anzeigen -
Maintenance principle of fluorinated liquid TCU temperature control system
927Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place; (2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m; (3) The lo...
Details anzeigen