Pay attention to the installation of high and low temperature cooling circulator
The high and low temperature cooling circulators can only be operated better if they are installed correctly. If the installation is not in place during the installation process, the high and low temperature cooling circulators will have certain hidden dangers in operation. What are the hidden dangers?
When installing the high and low temperature cooling circulator, it is necessary to pay attention to the refrigerant pipe entering the dust impurities, which will cause the cooling effect of the high and low temperature cooling circulator to decrease, and increase the wear of the high and low temperature cooling circulator compressor, thereby causing the high and low temperature cooling circulator group to be generated. Blockage, affecting the cooling effect. For the refrigerant pipe, it is necessary to pay attention to the refrigerant pipe leakage problem. If the leakage problem occurs, the overall cooling effect of the high and low temperature cooling circulator will be reduced. During this period, the long-term overheating operation of the compressor is extremely easy to make the life of the high and low temperature cooling circulator decline.
When the high and low temperature cooling circulator is installed, if the line is installed incorrectly, it will accelerate the damage of the electrical components, and may even cause the unit to operate in a chaotic manner, so that the individual control or centralized control cannot be realized, and the high and low temperature cooling circulator system cannot operate.
Wuxi Guanya LNEYA high and low temperature cooling circulator will produce condensed water during the process of cooling. The smooth discharge of condensed water will affect the installation of high and low temperature cooling circulators. The condensate pipes will be taken out from the internal machine to the outside or to the floor drain. Maintain at least >1% slope. When the discharge of the condensate line of the high and low temperature cooling circulator is insufficient, the unit may leak water and cause a short circuit of the power supply.
When installing the high and low temperature cooling circulator, it is necessary to prevent the outside of the equipment from being blocked within 1 meter. All the landing feet must be equipped with shock absorbing blocks to ensure that the high and low temperature cooling circulators operate normally. If the high and low temperature cooling circulator is improperly installed, the airflow will be short-circuited, and the protection switch action caused by the short-circuit of the airflow will cause the noise of the high and low temperature cooling circulator to affect the surrounding environment.
Therefore, the installation of high and low temperature cooling circulators should be careful to avoid improper installation and avoid these faults, and strive to make the high and low temperature cooling circulators operate effectively.
Verwandte Empfehlungen
-
Wie kann die Lebensdauer des dynamischen Temperaturkontrollsystems gewartet und verlängert werden?
1425Dynamic temperature control system is a fully enclosed refrigeration and heating temperature control device that provides cold and heat sources. The service life is related to the usual maintenance and cleaning. Dynamic temperature control system...
Details anzeigen -
Operation method of reaction kettle for circulating heating device
1709The laboratory single-layer glass reactor equipped with the circulating heating device can place a flask containing the reaction solvent on the inner layer for stirring reaction, and the interlayer can realize constant temperature heating and cons...
Details anzeigen -
Wie lässt sich das Problem des Ausfalls der Umwälzpumpe der Kühlanlage lösen?
1692Kühlung Heizgeräte sind in vielen chemischen, pharmazeutischen und Laboranwendungen erforderlich. Dann, wie das Scheitern der Kühlung Heizung Gerät zu lösen ist auch besorgt über, wie es zu lösen? 1. Ausfall der Umwälzpumpe Die Umwälzpumpe...
Details anzeigen -
How to use the reactor thermostat?
1588The reactor thermostat is generally heated by a resistance wire, cooled by a compressor, and is supplemented with a PID controller to maintain a relatively standard temperature, so as to achieve the purpose of the experiment. The shell is made of ...
Details anzeigen