Vorsichtsmaßnahmen für den Betrieb von Ethylenglykol-Niedrigtemperaturkühlern bei minus 30 Grad
The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly, it will cause a short service life.
Refrigerant leakage will not only affect the refrigeration efficiency of the minus 30 degree ethylene glycol utra-low temperature chiller, but also may affect the health of the personnel entering and leaving the equipment room due to refrigerant leakage, so the refrigerant leakage problem must be paid attention to.
Under normal circumstances, the refrigerant is not a consumable item, so it will not be missing frequently. If it is frequently or suddenly missing, it is recommended to check whether the refrigerant of the minus 30 degree ethylene glycol utra-low temperature chiller has leakage problems. If there is a leakage problem, it should be timely Find the leakage point and make up for the leakage, or replace the relevant refrigerant pipelines and connectors. If necessary, forced ventilation should also be performed.
The second is the load. To put it bluntly, it is not just the load of the compressor. The compressor must be coordinated with the machinery including the condenser, evaporator, expansion valve, etc. to be able to normally cool. In addition, there are water pumps and water towers or air-cooled utra-low temperature chiller. Fan systems, etc., these are compatible with each other. If the load of the utra-low temperature chiller exceeds the standard, it will not just be that the compressor is not enough, and all other parts and components will have the problem of excessive pressure! Larger loads, or exceeding the rated load, will cause overload and will affect more serious problems, including a series of problems such as decreased cooling efficiency, increased noise, increased vibration amplitude, excessive consumption of electrical resources, reduced life, etc. requires attention!
It can be said that the parameters related to temperature and pressure are important parameters of the minus 30 degree ethylene glycol utra-low temperature chiller. Enterprises should pay attention to the parameters related to the temperature and pressure of the equipment, and solve problems in a timely manner. In the process of use, we also need to pay attention to its maintenance and use instructions. Lneya provides minus 30 degrees ethylene glycol utra-low temperature chiller equipment to provide users with professional after-sales service.
Verwandte Empfehlungen
-
The Phenomenon of Ice Jam in Low Temperature Chiller System
1307The phenomenon of ice jam in low temperature chiller system is mainly due to the excessive water in the refrigeration system. With the continuous circulation of refrigerants, the water in the refrigeration system gradually concentrates at the outl...
Details anzeigen -
Description of Selection of Air-cooled Cryogenic Chiller
1837Many users struggle with the problems of air-cooled cryogenic chillers and water cooled cryogenic chillers. However, enterprises should make choices according to their actual environment. For this reason, Wuxi Guanya professional manufacturer has ...
Details anzeigen -
Auswirkung und Lösung der Abgasübertemperatur von industriellen Kühlanlagen
1703Die Abgastemperatur des Kompressors einer industriellen Wasserkühlmaschine entscheidet darüber, ob die Anlage stabil und effizient arbeiten kann. Das häufigste Problem bei Kompressoren ist eine zu hohe Abgastemperatur. Sobald die Situation auftritt, ist es einfach, die industrielle...
Details anzeigen -
Was sind die gebräuchlichen Kältemittel für die Markenauswahl von Kaltwassersätzen?
1778When the enterprise chooses the refrigerant in the cryo chillers unit brand, what should it need to pay attention to the present market commonly used refrigerant? What is the difference between specific refrigerant properties? Take a look at the b...
Details anzeigen