Ultra-low temperature refrigeration equipment is mainly used in industrial cold processing. Unlike some manufacturers of ultra-low temperature refrigeration equipment, LNEYA ultra-low temperature refrigeration equipment uses environmentally friendly refrigerant, which is conducive to the operation of ultra-low temperature refrigeration equipment. If the ultra-low temperature refrigeration equipment does not cool, how to Solve it?
Generally speaking, if the ultra-low temperature freezer is not cooled, there are four main reasons. One is that the filter is clogged. When the filter is clogged, the dust on the condenser will accumulate more and more, and the refrigeration effect of the refrigeration equipment will be affected over time. . In the long run, it may even cause refrigeration equipment to fail to cool. Solution to filter blockage: Clean the filter regularly or irregularly. It is also possible that the coolant content is small, and the ultra-low temperature refrigeration coolant content is too small, which may cause the equipment to not absorb oil and reduce the cooling effect. Less coolant content Solution: Always check the coolant to see if the coolant level is maintained at high or low, and add coolant when the coolant is too low.

If the refrigeration equipment is not cooled, there may be a lack of refrigerant. In the refrigeration, after the refrigerant is used for a long time, the refrigerant will volatilize after a long use time, thereby affecting the cooling effect. Solution: Refrigerant may have certain harm to the human body, so if you encounter this situation, you should find a professional refrigeration equipment company to add. There is also the possibility that the ultra-low temperature refrigeration supply voltage is low or the power of the refrigeration equipment is insufficient, and the equipment may not be cooled.
In general, the reasons and solutions for the non-refrigeration of ultra-low temperature refrigeration equipment are as shown above. It is recommended to find that the refrigeration faults are resolved in time to avoid affecting the production of the enterprise.
Verwandte Empfehlungen
-
What should I do if the 30p Refrigerated chiller compressors are overheated?
1236When users purchase 30p Refrigerated chiller, they understand the internal configuration. The compressor is an important accessory in 30p Refrigerated chiller. If it overheats, 30p Refrigerated chiller will be unavailable, then 30p Refrigerated ch...
Details anzeigen -
Chip IC dedicated refrigeration heating test machine instructions
1031The semiconductor chip Chiller is a temperature test simulation used in semiconductor testing. As a professional manufacturer, LNEYA has a wide temperature orientation and high temperature rise and fall, and the temperature range is -92 ° C ~ 250 ...
Details anzeigen -
What Should Be Noticed In Detail When Installing A Precision Chiller?
1203First, when installation, everyone needs to check whether your cold water machine works normal, whether the accessories are all right, whether there is damage, so as to avoid problems in installation. Second, when installing, the site of the preci...
Details anzeigen -
The difference between air-cooled and water-cooled 15P refrigeration units
1168Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference? The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, w...
Details anzeigen