High and low temperature circulation tank daily use instructions
During the operation of the high and low temperature circulation tank, some phenomena generated by the LNEYA protection device need to be observed. If some improper sounds and unexpected situations occur, we need to solve it in time.
The high and low temperature circulation tank is not connected to the power switch, forget to turn on the leakage circuit breaker, and turn the leakage circuit breaker to ON. There is no input from the power supply: the fuse is burnt. In order to ensure the safe and reliable operation of the refrigeration system and prolong the service life of the compressor, please pay attention to daily maintenance. Before starting the compressor, pay attention to whether the valve to be opened in the exhaust cut-off valve and its system is in the correct position, and check whether the power supply voltage and ambient temperature are within the specified range. During the operation of the compressor, the suction and exhaust pressure of the compressor should not exceed the range of use, and the operation sound of the compressor should be heard. Except that the intake valve and exhaust valve have clear pouring sound, other parts should not be knocked. When the sound is heard, it is found that the leak should be repaired in time. When the compressor is stopped for a long time, the refrigerant should be recycled to the reservoir and the exhaust shutoff valve should be closed.

The high and low temperature circulation tank adopts a fully closed pipeline design and adopts a high efficiency plate heat exchanger. It is applied to the temperature rise and temperature control of the glass reactor, metal reaction kettle and bioreactor, especially suitable for heat and release during the reaction process. Thermal process control. The high and low temperature circulation tank is applied to the temperature rise and temperature control of the glass reactor, the metal reaction kettle and the bioreactor, and is particularly suitable for controlling the heat demand and the heat release process during the reaction process.
Every accessory in the high and low temperature circulation tank is very important. Once the fault occurs, it needs to be solved in time. In the process of running, pay more attention to the maintenance in time to ensure the efficient operation of the accessories.
Verwandte Empfehlungen
-
LNEYA’s 300,000 kcal air-cooled unit on air tightness
1091When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
Details anzeigen -
Recommendations for the use of integrated chip test equipment in the test process
1027From the perspective of the entire semiconductor industry, semiconductors can be divided into R & D, production, and application stages. At different stages, the role of testing is different. Control of test equipment, including test machines,...
Details anzeigen -
Wie geht man mit Chipausfällen bei der Prüfung integrierter Schaltkreise um?
1174The integrated circuit chip test is used in various chips, semiconductors, and component tests. Once the chip fails, the test work will stop. Therefore, the ineffective user of the integrated circuit chip test needs to know clearly. The purpose of...
Details anzeigen -
LNEYA low temperature chiller selection classification description
1265Different enterprises and different industries have different requirements for the low-temperature chiller of Wuxi Guanya (LNEYA). The choice of models is also different, so it is better to understand them in the selection. The low temperature chi...
Details anzeigen