UST-Serie
ANWENDUNGEN
Suitable for temperature control in more usage scenarios
Used with reactors, reactors, microchannels, distillation systems, etc., and also used for heating and cooling of other equipment. Widely used in pharmaceutical, chemical, biological, semiconductor, new materials and other industries
Produktmerkmale
Produkt-Parameter
Modell | UST-5530 UST-5530W | UST-7530 UST-7530W | UST-A1030 UST-A1030W | UST-A1530 UST-A1530W | UST-A2530 UST-A2530W | UST-A3830 UST-A3830W | UST-A6030 UST-A6030W | UST-A9530 UST-A9530W | |
Temperaturbereich | RT+10℃~+300℃ | ||||||||
Kontrollsystem | PID-Rückführung + unsere spezielle dynamische Regelberechnung, PLC-Regler | ||||||||
Kontrollmodus | Process temp control and jacket temp control mode | ||||||||
Temp difference | Einstellung oder Kontrolle des Temperaturunterschieds zwischen Mantelöl und Rohmaterialprozess | ||||||||
Programm-Editor | 5 Programme, jedes Programm kann 40 Schritte bearbeiten | ||||||||
Communication protoco | MODBUS RTU Protokoll, RS485 Schnittstelle | ||||||||
Material temp feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Rückmeldung zur Temperatur | The temp of three points: the inlet and outlet of equipment, reactor material temperature(external temp sensor) | ||||||||
Medium temp acccuracy | ±0.5℃ | ±1℃ | |||||||
Material temp accuracy | ±1℃ | ||||||||
Heizleistung kW | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
Kühlung Kapazität |
300 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 |
200 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
100 ℃ | 4 | 5 | 7 | 12 | 20 | 30 | 48 | 76 | |
65 ℃ | 1.8 | 2.2 | 3 | 5 | 8.5 | 12 | 19 | 30 | |
Umwälzpumpe max L/min bar |
35 | 50 | 50 | 110 | 150 | 200 | 250 | 400 | |
2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Bedienfeld | 7-inch touch screen, show temp curve\EXCEL data output | ||||||||
Schutz der Sicherheit | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, high temperature protection and temp fault protection |
||||||||
Closed circulation System |
The whole system is full closed circulation, there is no oil mist at high temp and no water vapor at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature |
||||||||
Connection siz | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Connection size(water port) | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Abmessung cm | 40*70*130 | 45*70*160 | 40*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | |
Gewicht kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 950 | |
Power MAX 380V 50HZ |
7kW | 9kW | 12kW | 17kW | 28kW | 41kW | 65kW | 96kW | |
Shell materia | Cold rolled sheet (REL7035) |