Suche im gesamten Bahnhof

Temperture Forcing System/ Jet Impact Testing Machine

ZLT HED Series 10℃~60℃

Chemical medium temperature control unit
  • Genauigkeit der Temperaturregelung±0.1℃
  • Heating capacity2KW~7.5KW
  • Kühlleistung1KW~6KW

Detaillierte Parameter

Modell ZLT-1HED ZLT-3HED ZLT-6HED
ZLT-1WHED ZLT-3WHED ZLT-6WHED
Temperaturbereich 10 ℃~+60℃ Different media, different temperatures
Genauigkeit der Temperaturregelung ±0.1 ±0.1 ±0.1
Kühlleistung 20 1kW 3kW 6kW
Heating capacity 2kw 3.5kw 7.5kw
Direct cooling method Kompressor
Input, display 4.3-inch/7-inch color touch screen\ PLC controller
Kommunikation Modbus RTU protocol RS485 interface, Ethernet TCP/IP protocol
Heat exchanger Silicon carbide
Größe der Schnittstelle G3/8 G3/8 G1/2
Water-cooled @20℃ 300L/H 800L/H 1500L/H
G3/8 G3/8 G1/2
Water-cooled condenser The condenser of the water-cooled equipment adopts a plate heat exchanger
Air-cooled condenser Microchannel-Wärmetauscher Microchannel-Wärmetauscher Microchannel-Wärmetauscher
Stromversorgung Single phase 220V Three-phase 380V/220V
Chemical pipe material PFA
Casing material Cold rolled sheet spraying (REL7035)

Send us a message about ZLT series
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Recommended products

  • MD Series Chuck"      /&gt;<figcaption><span>Quick temperature change control chuckConfiguration DetailsProduct Description           -75℃ to 225°C          Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…</span></figcaption></figure></a></div><div class= MD Series Chuck

    Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…

  • YQH 0℃~-75℃"      /&gt;<figcaption><span>Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products        Suitable for the recovery of various volatile VOCs gases; Fast c…</span></figcaption></figure></a></div><div class= YQH 0℃~-75℃

    Product data downloadVOCS gas condensation capture and recoveryWhere do harmful gases come from?parameterworking principleCustomized 25 BAR-40~-75℃recommend products Suitable for the recovery of various volatile VOCs gases; Fast c…

  • FLT-100℃~90℃"      /&gt;<figcaption><span>chillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products                                                                          Single channel air-cooled cooler, mainly desi…</span></figcaption></figure></a></div><div class= FLT-100℃~90℃

    chillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Single channel air-cooled cooler, mainly desi…

  • FLTZ -45℃~90℃"      /&gt;<figcaption><span>Product data downloadTemperature control in semiconductor production and testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endProductDescriptionchillers that control the processing temperature on…</span></figcaption></figure></a></div><div class= FLTZ -45℃~90℃

    Product data downloadTemperature control in semiconductor production and testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endProductDescriptionchillers that control the processing temperature on…

Laden...

已经是到最后一篇内容了!

Erweitern Sie mehr!