Routinewartung der Multireaktor-Temperiergeräte der tcu

TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universities, enterprise quality inspection and production departments to provide users with a liquid environment with controlled cold and hot, uniform and constant temperature when working.
1. Tcu multi-reactor temperature control equipment is a heating equipment that can control the temperature of the reaction material by heating the heat transfer oil in the jacket of the reactor to transfer heat energy to the material in the reactor indirectly.
2. The whole liquid circulation is a closed system. There is no absorption of water vapor at low temperature and no oil mist at high temperature. The heat transfer oil can work at a wide temperature; The same machine and the same heat conduction medium can realize continuous temperature rise and fall control.
3. Equipped with a heating and cooling integrated container, the heat exchange area is large, the heating and cooling rate is fast, and the demand for heat transfer oil is relatively small. It can realize continuous temperature rise and fall. Refrigeration heat exchanger adopts plate heat exchanger with high heat exchange efficiency and small floor area.
4. It has self-diagnosis function, refrigerator overload protection, high-voltage pressure switch, overload relay, thermal protection device and other reliable guarantee functions, fully ensuring reliable use;
5. In case of power failure, use dry compressed air regularly to clean the inside of the machine’s electric box and heat dissipation dust to avoid electrical failure caused by metal residues falling on the electrical components;
6. During normal use, use dry compressed air regularly to clean the metal residue and dust on the fan cover of the pump inside the machine to prevent the motor from radiating poorly after the fan cover is blocked, which may cause abnormal noise or jamming of the pump motor;
7. During long-term use, regularly maintain or replace other machine parts according to other requirements in the manual. In case of shutdown, regularly clean the filter at the oil return port of the machine to avoid over-temperature alarm and other faults caused by filter blockage; Customers can formulate effective maintenance plans according to the use of the machine and the site environment.
Verwandte Empfehlungen
-
Performance Characteristics of 30 HP Water Cooled Chiller
1058The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for coo...
Details anzeigen -
LNEYA high and low temperature heating refrigerator maintenance instructions
1138High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high an...
Details anzeigen -
Wartung des Glykol-Kühlungs-Heizungs-Regelsystems
1115Abgesehen von der Aufmerksamkeit, die während des täglichen Gebrauchs erforderlich ist, sind die regelmäßige Überprüfung und Wartung des Glykol-Kühlungs-Heizungs-Regelsystems ebenfalls sehr wichtig. Um Ihnen zu helfen, lernen, Glykol Kühlung Heizung effizienter zu nutzen, LNEYA Ref...
Details anzeigen -
battery charging test conditions at different ambient temperatures
1237At present, the battery is undoubtedly the most core and critical component in electric vehicles. Therefore, both the OEM and the battery factory need to conduct a comprehensive test of the battery. The characteristics of automotive lithium-ion po...
Details anzeigen