Introduction to the quality and configuration of industrial refrigeration and heating circulators
With the development and progress of society, industrial refrigeration and heating circulators are used more in the industry, and the technological level is becoming more and more complex. So, what should users pay attention to after purchasing this equipment?

1. In order to consume electricity, many companies will cut off the power after the experiment. According to the technical staff, we explained that if the industrial refrigeration and heating circulator is powered off in winter, the inner tank is prone to aging, thereby reducing the equipment’s performance. service life.
2. During normal use, when the temperature in the box drops to a certain set value, the thermostat will cut off the power by itself. At this time, the pressure of the refrigerant is already very low, and the compressor is relatively small compared to the load of the motor. , the motor is easy to start normally, if the power is forced to be cut off, the power will be turned on immediately when the refrigeration has a relatively high pressure. Although the high voltage will cause the motor to be overloaded, it is easy to burn the motor due to excessive current. Therefore, industrial refrigeration and heating circulators cannot be powered off at will.
3. The industrial refrigeration and heating circulator that is in a power-off state cannot be powered on at will, especially for newly purchased equipment, it must be placed for one to two hours before it can be powered on.
4. There is a certain space between the inner tank and the outer shell. The electric heating tube is used to provide heat to transfer the heat to the heat-conducting oil medium, and then the heat is transferred to the inner tank of the reactor through the heat-conducting oil bath, and the material medium in contact with the inner tank passes through the steel plate. The heat is used to increase the temperature, and the temperature required for the reaction of the material is slowly reached.
5. The electric heating tube is generally 220v/380v voltage, and the 220v electric heating tube must be three in a group, connected to form three power supply requirements (general industrial production does not use direct single-phase wiring), through three in a group, you can According to the total number of electric heating pipes required, multiple groups are formed.
There are certain differences in the quality and configuration of industrial refrigeration and heating circulators from different manufacturers. Users can judge and use them according to the reaction kettle heating and temperature control machine they purchased.
Verwandte Empfehlungen
-
LNEYA Elektroauto-Motor-Umlaufkühlsystem Schmiermittel Beschreibung
1159Electric vehicle motor circulating cooling system is used in new energy vehicle battery testing. So the performance requirements are very high. Among them, the lubricating oil of the electric vehicle motor circulating cooling system has a certain ...
Details anzeigen -
Vorsichtsmaßnahmen für den Betrieb von Ethylenglykol-Niedrigtemperaturkühlern bei minus 30 Grad
1032Der Minus-30-Grad-Ethylenglykol-Ultraniedrigtemperaturkühler ist ein Gerät, das eher in der pharmazeutischen und chemischen Industrie verwendet wird. Wenn Sie es verwenden, müssen Sie auf seine Betriebsspezifikationen achten, um es zu betreiben. Bei unsachgemäßer Verwendung,...
Details anzeigen -
Hoch- und Niedertemperatur-Heiß- und Kaltwasserkühlmaschine für den Test von Batteriemotoren
1042LNEYA Hoch- und Niedertemperatur-Kalt- und Warmwasserkühler werden für das Wärmemanagement der Batterie von Elektrofahrzeugen mit neuer Energie verwendet. Das folgende ist das relevante Prinzip im Wärmemanagement angewendet.die hohe und niedrige Temperatur kalt und...
Details anzeigen -
What should we pay attention to when purchasing cooling equipment for industrial chiller units?
810When many customers buy refrigeration equipment for industrial chiller units, they don't know what the key points are. Next, let me talk to you. 1. It should be determined according to the use, refrigerating capacity, local power supply, water sou...
Details anzeigen