Wie lässt sich das Kühlproblem bei großen Schnellkühlkompressoren lösen?
There are many types of compressors in large-scale quick-freezers, and the brands and models of compressors are different according to different models. Once the compressor temperature is too high, it may cause some failures, so cooling is also an important task.
In the operation of large-scale quick-freezer compressors, cooling is an indispensable part. The compressor should always pay attention to the cooling water. Once the water is cut off, it must be stopped immediately for inspection. Components that require water to be cooled by the compressor include cylinders, intercoolers, compressor aftercoolers, and oil coolers.
For large freezer cylinders and intercoolers, one of the purposes of cooling is to reduce the exhaust temperature so that the exhaust temperature does not exceed the allowable range. It can be seen that after the large-scale quick-freezer compressor is shut off, the cylinder and the intercooler are not cooled, and the exhaust temperature of the compressor rises sharply. This not only causes the lubricating oil in the cylinder to lose lubrication performance, but also causes the moving parts to wear rapidly, and the lubricating oil is decomposed, and the volatile components in the oil are mixed with the air, causing accidents such as burning and explosion.
For large-scale quick-freezer compressor oil coolers, the water loss of the Wuxi Guanya LNEYA compressor will result in poor cooling of the lubricating oil and an increase in the temperature of the compressor lubricating oil. In this way, the viscosity of the lubricating oil is lowered, the lubricating performance is deteriorated, the wear of the moving parts is intensified, the life of the machine is reduced, the power consumption is increased, and the lubricating oil is decomposed, and the volatile components in the oil are mixed into the air, causing an accident.
Overheating of the compressor will affect the operation of the large-scale quick-freezer, so it is recommended to do the cooling work in order to run smoothly.

Verwandte Empfehlungen
-
Betriebsanleitung für die Kältemaschine, ein Kreislaufsystem für die Temperierung von Laborprozessen
1059Das Wärmeträgermedium des Laborprozess-Temperaturregelkreislaufs verwendet Öl und Wasser. Das Wärmeträgermedium (Wärmeträgeröl oder Wasser), das in den Rohrleitungen zirkulieren muss, wird durch eine elektrische Heizung erwärmt...
Details anzeigen -
Tipps zur Erkennung von Leckagen bei Tiefkühltruhen
1143Druck LeckerkennungEs ist ein effektiver Weg, um zu überprüfen und herauszufinden, die Leckstelle. Die Leckageerkennung Druck der Kühlanlage des Gefrierschrankes ist relevant für die Art der Kühlflüssigkeit und Kühlung und die Lage der Röhre. Die Le...
Details anzeigen -
-
Einführung in Niedertemperatur-Kühlgeräte
1142Low Temp Chiller ist eine Art von Kühlgeräten, die Kältequelle unter 0℃ zur Verfügung stellen kann. Es bezieht sich im Allgemeinen auf die Verwendung Temperatur von 5 bis 35℃. Das Kältemittel kann durch Ethylenglykol oder Calciumchlorid wässrige Lösung getragen werden, und die...
Details anzeigen