How to prevent the freezing pressure of the bearing quick freezing box from being too low?
In the refrigeration system of the bearing blast chiller, if the condenser installation is not in the enclosed space, the system’s exhaust pressure (condensation pressure) tends to be lower in winter (or low temperature), which is often more common in the north. For bearing blasters, this is also the case for other equipment.
The low condensing pressure of the bearing quick freezing box will make the expansion valve unable to obtain sufficient pressure drop at both ends, and it is difficult to supply the appropriate refrigerant to the evaporator. On the one hand, the cooling capacity of the refrigeration system will not meet the requirements, and the system will also be made. Frequent low-voltage alarms and other faults.
To this end, we can deal with the method of exhaust pressure controller. When the intermittent operation of the fan is simple and easy to use, and the technology is mature, the controller used is a pressure controller. This pressure controller can control the intermittent start and stop of the fan. When the pressure is too low, turn off the fan. When the pressure is too high, turn on the fan. Generally, on a small-capacity unit, use two or more fans, one of which is normally open, and the other fans are pressure controlled. The controller controls the start or stop of the fan by the level of the condensing pressure.
It is also possible to use a pneumatic control device to utilize a high-pressure refrigerant-driven piston-type damper. This control device can operate as a stable exhaust pressure as the fan speed controller; the main reason is that the inlet pressure of the expansion valve does not resemble a fan. Intermittent operation produces large fluctuations, and the louver device can be installed either at the air inlet or at the air outlet.
In addition, the condenser overflow device can also be used to increase the condensing pressure of the system by using excess refrigerant, and the condenser overflow device is used for warming or low temperature environment, and the large flow refrigerant is taken from the liquid storage device. It is sent to the condenser, and the excess refrigerant is used to increase the condensing pressure of the system, thereby avoiding the failure of the condensing pressure being too low at low temperatures.
LNEYA’s methods to prevent the bearing chiller from condensing too low pressure are still relatively high, and users can try it according to their own needs.

Verwandte Empfehlungen
-
5P Warm- und Kaltwassermaschine Installationsanleitung
1038The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
Details anzeigen -
Wie wichtig ist die Isolierung der Kältemaschine?
1290Answer: For the chiller, if it is operated at high temperature, a large amount of cold air in the industrial chiller may be severely lost. After the sealing effect of the use environment, through timely and effective heat preservation, the operati...
Details anzeigen -
How to solve the problem of returning oil in ultra-low temperature freezer?
1481The ultra-low temperature freezer will fail after a long period of use, and the user needs special attention when oil return occurs. In the ultra-low temperature freezer, the oil return is not smooth, which will cause a large amount of lubricating...
Details anzeigen -
Analyse der Gründe für die Nichtkühlung kryogener Kühlanlagen
1075Ultra-Niedrigtemperatur-Kälteanlagen werden hauptsächlich in der industriellen Kälteverarbeitung eingesetzt. Im Gegensatz zu einigen Herstellern von Ultra-Niedrigtemperatur-Kälteanlagen verwendet LNEYA Ultra-Niedrigtemperatur-Kälteanlagen umweltfreundliche...
Details anzeigen