Wie kommt es zu Ablagerungen bei der Nutzung des Kühlers?
A chiller is a water-cooled unit that uses water circulation to provide a constant temperature, constant flow and constant pressure cooling water. The LNEYA cold water system has its own working principle, that is, a certain amount of water is injected into the water tank of the machine, the cooling water is cooled by the refrigeration system, and then the cooling water is operated by the compressor. The cooling water is sent to the equipment to be cooled, the heat is taken away, then the temperature rises, and then flows back to the water tank to achieve a cooling effect. However, when using a chiller for a long time, there will usually be some dirt deposits in the chiller pipe or water tank. What is the reason below.
1.Chemical processor
If a zinc salt or a phosphate inhibitor is added to the water circulation system, zinc or phosphate scale is formed. Therefore, we must always carry out maintenance work on the chiller, not only to ensure the cooling capacity, but also to extend the service life of the chiller.
2. Process media leakage
The water cooler leaks, especially if it leaks oil or some organic matter causes deposits to form.
3. Air
Sediments, dust, microorganisms and their spores enter the circulatory system with the air, and sometimes insects are carried into the system, causing the heat exchanger to clog. When the environment surrounding the cooling tower is contaminated, corrosive gases such as hydrogen sulfide, chlorine dioxide and ammonia will react in the unit and indirectly cause deposition.
The LNEYA chiller cooler is a fully enclosed system that does not expose the media to outside air during use.
It can be seen from the above that in the use, the chiller needs to be maintained at all times, which not only ensures the cooling capacity, but also prolongs the service life of the chiller and the saving of circulating water.
If you need any information, you can contact LNEYA to inquire about the use of chiller coolers and other cooling system equipment at sales@lneya.com/LNEYA.COM.

Verwandte Empfehlungen
-
The Application of Cold Plate Freezer
1007The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston compressors, semi-hermetic piston compound compress...
Details anzeigen -
Advantages of Industrial Chillers in Refrigeration
1124In recent years, the manufacturing industryhas entered a golden age. The market competition is fierce, and therequirements for product quality have been greatly improved. In fact, in theprocess of improving product quality, manufacturers oft...
Details anzeigen -
Pharmaceutical WFI system low-temperature cooling water circulator/chiller
821The WFI (Water for Injection) system in the pharmaceutical industry is a highly purified water system that provides sterile water that meets strict quality standards for drug production and formulations (such as injections). ...
Details anzeigen -
Troubleshooting of refrigeration system failure of material aging test equipment at low temperature
1075Regular maintenance work for the material low temperature and high temperature aging test system, and troubleshooting of the refrigeration system is also very important. Here are a few tips. 1. Exhaust at double high pressure, heat dissipation ma...
Details anzeigen