Vorsichtsmaßnahmen für die Verwendung einer Kühlfalle mit einem kryogenen Flüssigkeitsbad von minus 95 Grad
The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also make the cooling effect more stable.
1. Before using the minus 95 degrees low temperature liquid bath cold trap, you must carefully read the instructions for using the minus 95 degrees low temperature liquid bath cold trap, and then perform the correct installation, commissioning and normal use steps of the equipment.
Second, the minus 95 degrees low temperature liquid bath cold trap should be installed in a stable, ventilated and open place, and the ambient temperature of the installed unit should not exceed 38-40 ℃. After all, the minus 95 degree low temperature liquid bath cold trap is cooled by the fan to exchange air. The temperature is too high and the heat dissipation is not good, then the temperature of the unit will not drop, or there will be a high pressure failure.
3. The tap water can be filtered to ensure that the water quality is clean and free of impurities. The piping of the unit should be installed reasonably, and the size of the pipeline hose should be matched with that of the unit. The size of the water pipe should not be reduced. Otherwise, it will be prone to high-pressure overload, which will affect the quality effect and increase power consumption.
Four, our commonly used minus 95 degrees low temperature liquid bath cold trap power supply is 3-phase 380V 50HZ (1p minus 95 degrees low temperature liquid bath cold trap/2p air-cooled chiller is 220V), so when the unit is connected to the electrical system , Be sure to connect the corresponding power supply voltage according to the nameplate. In addition, the power supply of units going abroad will be different.
Five, pay attention to the operation sequence of the unit. After connecting the unit to the equipment requiring refrigeration, first turn on the power to the ON position, then turn on the chilled water pump switch, and open all the inlet and outlet valves of the chilled water. After the compressor starts to cool, the chilled water will pass through The water outlet is delivered to the cooled equipment. When shutting down the unit, just shut down in the reverse order.
6. When the minus 95 degree low temperature liquid bath cold trap fails, the corresponding indicator light on the control panel of the unit will light up and emit a warning sound. At this time, the unit should be shut down and checked in time. When the company does not have a professional unit maintenance personnel, please firstly freeze the manufacturer, and let the manufacturer guide or arrange the maintenance personnel to deal with it.
Verwandte Empfehlungen
-
How to choose the right hot and cold circulator?
1036The hot and cold circulator is widely used in the pharmaceutical and chemical industry to provide users with hot and cold controlled, uniform temperature and constant temperature. It can also be directly equipped with reactors, reactors, etc. fo...
Details anzeigen -
LNEYA erhält zum dritten Mal die Zertifizierung als nationales High-Tech-Unternehmen
2849In November 2021, the Science and Technology Department of Jiangsu Province released the "2021 High-tech Enterprise Record Publicity List in Jiangsu Province", and LNEYA successfully passed the review. This is the third time that the company has...
Details anzeigen -
Exhibition Preview | 2019 China International Automotive Testing Quality Monitoring Expo
1177Autumn is cool, the exhibition season is here again!For you to present Wuxi Guanya LNEYA exhibition information: We invite you to attend:2019 China International Automotive Testing and Quality Control ExpoExhibition time: September 24-26Exhibi...
Details anzeigen -
Fehlerbehebung bei Lüfterausfällen im Kühlsystem des Motorantriebsstrangs
959The fan is generally installed at the upper end of the cooling system of the engine powertrain, and some customers choose to install it on the side according to regulations. For screw chillers that use fans to dissipate heat, they are called air-c...
Details anzeigen