Tips for Leakage Detection of Low Temperature Freezer
Soaking leakage detection
The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharged, like all kinds of relays and electrical control device. Taking advantage of warm water during the bubble test, because its surface tension is smaller than cold water, forming bubbles more easily. As an editor of Low Temperature Freezer, I want to tell you that the leakage point will be discovered simply if accompanied by intense light source. After the completion of soaking leakage detection, the surface ought to be dried with compressed air, preventing the metal from corrosion.
Halide torch and its leakage detection
These are the specialized devices for detecting the Freon freezer unit system. When Freon refrigerating fluid encounters hot cooper parts, different colored flames will be casted for F2, C12 and Br contain the elements of halogen, helping find out the leaking point.
Vacuum leak test
When freezer unit system passes the pressure leakage detection, it should also go through the vacuum leak test since some pasts exist one-way leaker. Only pressure and vacuum leakage detection both conform to the standard can the leakproofness of cooling system can be ensured. Besides, the system is evacuated, so can water at the same time , esped dcially the Freon system. Therefore, evacuation and desiccation play essential roles in debugging the unit.
Should the uses for low temperature freezer be understood, the users will have a better try! Visit LNEYA to know more about low temperature freezer price.
Verwandte Empfehlungen
-
Low temperature refrigeration unit maintenance inspection
1067Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the com...
Details anzeigen -
What are the temperature control performance of laboratory recirculating chillers
1017The laboratory recirculating chiller is atypical cooling circulator with heating function to ensure the repeatability oflaboratory results. There are water-cooled or air-cooled refrigerators, whichcan be placed in a laboratory fume hood or set ...
Details anzeigen -
Introduction to the quality and configuration of industrial refrigeration and heating circulators
858With the development and progress of society, industrial refrigeration and heating circulators are used more in the industry, and the technological level is becoming more and more complex. So, what should users pay attention to after purchasing th...
Details anzeigen -
The Advantage Parameter Explanation Of The Walk-In Lab Water Chiller
910In the experimental equipment, the walk-in lab water chiller is used for all kinds of electronic components in high and low temperature or hot and wet environment to test the requirements of various performance indicators. It is generally applicab...
Details anzeigen